CardioBoardExam.com

Library › Coronary artery disease › Coronary angiography and FFR

Cardiac catheterization, coronary angiography and FFR

Diagnostic cardiac catheterization in adults from indications, consent, and left heart catheterization through angiographic anatomy, projections, lesion and flow grading, graft angiography, and pressure-wire and angiography-derived physiology with the trials and guideline recommendations behind them.

Angiography shows the coronary lumen; physiology shows whether a narrowing limits flow. A fractional flow reserve (FFR) of 0.80 or less, or a nonhyperemic pressure ratio of 0.89 or less, identifies a hemodynamically significant stenosis. In chronic coronary disease, FFR or a nonhyperemic ratio is recommended before percutaneous coronary intervention (PCI) of an angiographically intermediate lesion (Class 1). Epicardial flow is graded with the Thrombolysis in Myocardial Infarction (TIMI) flow grade and frame count, tissue perfusion with the blush grade, and dissection, perforation, thrombus, and collaterals with their own validated scales.

Indications for cardiac catheterization and coronary angiography

Diagnostic cardiac catheterization combines selective coronary angiography with measurement of intracardiac pressures and, when needed, left ventriculography, right heart catheterization, oximetry, and pressure-wire physiology. Its purpose is a decision: whether and how to revascularize, whether a valve or myocardial disease explains the symptoms, and what the hemodynamic state is. Coronary CT angiography now answers the anatomic question in many patients with stable chest pain. DISCHARGE enrolled 3,561 patients with stable chest pain and an intermediate pretest probability who had been referred for invasive angiography. A CT-first strategy produced a similar 3.5-year rate of cardiovascular death, myocardial infarction, or stroke (2.1% vs 3.0%) and fewer major procedure-related complications (0.5% vs 1.9%).

The indications fall into four groups. In chronic coronary disease, invasive angiography is a decision tool for revascularization, used for symptoms or functional decline that persist despite guideline-directed therapy, new left ventricular dysfunction, or noninvasive findings that suggest high-risk anatomy. Routine risk stratification relies on noninvasive testing (indications in chronic coronary disease).

In acute coronary syndromes, angiography is the gateway to reperfusion or revascularization, and its timing is set by the syndrome and the patient's risk (ST-elevation myocardial infarction (STEMI) and primary PCI; timing of the invasive strategy in non-ST-elevation acute coronary syndromes (NSTE-ACS); angiography after cardiac arrest).

In valve and myocardial disease, coronary angiography precedes valve surgery or transcatheter valve replacement in patients with angina, ischemia, reduced ejection fraction, or coronary risk factors (aortic stenosis). Hemodynamic catheterization resolves discordance between clinical and noninvasive findings. In unexplained ventricular dysfunction, ventricular arrhythmia, or cardiac arrest, angiography establishes or excludes an ischemic cause.

Clinical settingQuestion angiography answersWhere the decision is detailed
STEMI or STEMI equivalentCulprit artery and immediate reperfusionPrimary PCI
NSTE-ACSCulprit lesion, extent of disease, PCI or bypassAngiography in NSTE-ACS
Chronic coronary disease with refractory symptoms or high-risk noninvasive findingsAnatomy and physiology before revascularizationChronic coronary disease
Abnormal coronary CT angiographyConfirmation and physiology of a stenosisCT-FFR and invasive FFR
Valve surgery or transcatheter aortic valve implantation (TAVI) plannedCoexisting coronary diseaseAortic stenosis
New cardiomyopathy or heart failureIschemic versus nonischemic causeChronic coronary disease
Angina with nonobstructive arteriesMicrovascular dysfunction or vasospasmCoronary function testing
Pulmonary hypertension, shunt, or hemodynamic evaluationPressures, output, resistance, shuntRight heart catheterization

Indications for diagnostic catheterization by clinical setting, with the hubs that hold the treatment decision.

Appropriate use criteria for diagnostic catheterization

The 2012 appropriate use criteria for diagnostic catheterization were issued by the American College of Cardiology Foundation (ACCF), the Society for Cardiovascular Angiography and Interventions (SCAI), and 10 other societies. They scored 166 clinical scenarios on a 1-to-9 scale: a median of 7 to 9 denoted appropriate use, 4 to 6 uncertain use, and 1 to 3 inappropriate use. Seventy-five scenarios were rated appropriate, 49 uncertain, and 42 inappropriate. Most scenarios addressed coronary angiography for the detection of coronary disease, with hemodynamic measurement and ventriculography at the operator's discretion; the remainder addressed hemodynamic study of valve disease, pulmonary hypertension, and cardiomyopathy. The criteria score clinical reasonableness and are distinct from the guideline classes of recommendation. For the detection and risk assessment of chronic coronary disease, testing strategies that include invasive angiography are rated in the 2023 multimodality appropriate use criteria (appropriate use of cardiac testing).

Contraindications, risk assessment, and preparation

There is no absolute contraindication to coronary angiography when the information will change management in a patient who accepts treatment. In emergencies, the procedure is performed despite conditions that would defer an elective study. Relative contraindications are conditions that raise the risk and can often be corrected first. They include acute kidney injury or advanced chronic kidney disease, decompensated heart failure that prevents lying flat, uncontrolled hypertension, active bleeding or severe coagulopathy, a supratherapeutic international normalized ratio, uncorrected hypokalemia or digoxin toxicity, untreated infection, recent stroke, a prior severe reaction to iodinated contrast, and pregnancy. Refusal of the treatment that the angiogram would lead to, such as surgery or PCI, makes an elective study unnecessary.

Preprocedural assessment documents the indication, symptoms and functional class, and a focused examination including the peripheral pulses and an access-site plan. It also records kidney function, hemoglobin, platelet count, coagulation status, potassium, prior contrast reactions, prior access difficulties and bypass operative notes, and the current anticoagulant and antiplatelet regimen. The management of oral anticoagulants before the procedure is covered on the periprocedural anticoagulation hub. Contrast-associated kidney injury, its risk scores, volume expansion, and contrast-sparing technique are covered on the contrast hub, together with contrast reactions and premedication. Metformin, diuretics, and insulin are adjusted according to kidney function and fasting.

Informed consent for catheterization is a process of shared decision-making. The patient is told the purpose of the study, how the result may change treatment, and the expected benefits. The discussion covers the material risks (bleeding and vascular injury, contrast reactions and kidney injury, arrhythmia, myocardial infarction, stroke, emergency surgery, and death), the alternatives including noninvasive testing and medical therapy, and the consequences of declining.

When PCI may follow in the same session, consent covers the intervention, its alternatives including bypass surgery and continued medical therapy, and the commitment to dual antiplatelet therapy after stenting. Consent is obtained before sedation by a clinician able to answer the patient's questions, in the patient's language with an interpreter when needed, and from a surrogate decision-maker when the patient lacks capacity. In an emergency such as STEMI with shock, implied consent permits life-saving treatment.

Ad hoc PCI. PCI performed in the same session as diagnostic angiography is the default in acute coronary syndromes. The 2013 SCAI consensus statement noted that randomized trials comparing ad hoc with delayed PCI had not been performed and that cohort studies found no consistent difference in safety or efficacy. For stable ischemic heart disease, it required preprocedural planning and reassessment after the diagnostic angiogram to confirm appropriateness. It also reviewed the patient subsets and clinical situations in which delayed PCI may be safer or yield better outcomes. Anatomy that may be better treated surgically, a large contrast volume already given, and a patient not yet counseled about the alternatives are common reasons to separate the two procedures.

Documentation. The procedure report records the indication, the consent, sedation and medications, access site and sheath size, catheters, contrast volume, fluoroscopy time and radiation dose, and hemodynamic measurements. It also records the dominance pattern, segment-by-segment stenosis grading with the projections that defined the stenoses, flow grades, collaterals, grafts and stents, physiology and imaging results, complications, the hemostasis method, and the plan. A segment that could not be visualized adequately is reported as such.

Laboratory standards. The 2021 SCAI expert consensus update on best practices in the catheterization laboratory, endorsed by the American College of Cardiology (ACC), the American Heart Association (AHA), and the Heart Rhythm Society, updated the 2012 and 2016 documents. It covers staffing and credentialing; preprocedural, intraprocedural, and postprocedural logistics; clinical standards and patient flow; laboratory governance and quality metrics; and the Heart Team approach.

Vascular access, sedation, and anticoagulation in outline

The radial artery is the default access for diagnostic angiography and PCI. In the 2021 ACC/AHA/SCAI revascularization guideline, radial access is recommended over femoral access in patients undergoing PCI to reduce bleeding and vascular complications (Class 1). In acute coronary syndromes, radial access also reduces mortality; the randomized evidence, including MATRIX, is summarized on the NSTE-ACS hub. Femoral access remains the route when radial anatomy is unsuitable, large-bore equipment or mechanical support is needed, graft engagement is easier from the groin, or radial access fails. Access technique, closure, and access-site complications are on the vascular access hub.

Diagnostic angiography is performed under local anesthesia with minimal or moderate sedation. Heparin is given intra-arterially after radial access to prevent radial artery occlusion, and it is also given during PCI. Unfractionated heparin is the Class 1 anticoagulant for PCI in the 2021 guideline unless contraindicated. Drug choice and dosing for parenteral anticoagulants are on the parenteral anticoagulant hub.

Diagnostic catheters and engagement of the coronary ostia

Preformed catheters are named for the shape of their distal curves and sized by the length of the segment between the primary and secondary curves, which is matched to the width of the aortic root. A catheter that is too small for a dilated root points upward and does not reach the ostium; one that is too large flips or seats deeply. Coaxial alignment of the tip with the proximal vessel is the goal, because a tip pressed against the wall dampens pressure and can dissect the ostium.

CatheterShape and behaviorTypical useHazard
Judkins leftPrimary and secondary curves; tip seeks the left ostium as it descends the ascending aortaLeft coronary from femoral or radial access; larger curve for a dilated root, smaller for a narrow rootDeep seating in a short left main
Judkins rightSingle curve rotated clockwise from the left cusp into the right cuspRight coronary arteryOstial dissection or spasm with excessive torque; poor coaxiality with a superior or anterior origin
Amplatz left and rightSecondary curve rests on the opposite aortic wall; tip directed upward or acrossSuperior or anterior right coronary origin, anomalous origins, vein grafts, dilated rootsDeep intubation; withdrawn by advancing slightly and rotating out
MultipurposeGentle distal angle, end hole with side holesLeft ventriculography, vein grafts, inferiorly directed right coronary originSide holes deliver contrast into the aorta during selective injection
Internal mammarySharp hooked tipInternal mammary artery grafts from the subclavian arteryDissection of the subclavian or internal mammary ostium
Right and left coronary bypass shapesCurves designed for anterior aortic graft ostiaSaphenous vein graftsOstial graft dissection
Radial universal shapesSingle curve that engages both coronary arteriesRadial angiography with one catheterLess coaxial in tortuous or dilated roots
PigtailCoiled end with side holesLeft ventriculography and aortographyVentricular ectopy during injection

Diagnostic catheter shapes and their use.

Before contrast is injected, the pressure waveform at the catheter tip is examined. A damped or ventricularized waveform means the tip is obstructing the ostium because of catheter position, ostial disease, or spasm. Injection in that position risks dissection and ischemia (damping and ventricularization). An ostium that cannot be engaged after appropriate catheter exchanges is localized with a nonselective injection in the sinus or with aortography; an anomalous origin is suspected when a vessel is absent from its expected sinus.

Radiation exposure and contrast use during angiography

Angiography exposes the patient and staff to ionizing radiation. Patient dose rises with fluoroscopy time, cine runs, steep angulation, body size, and magnification. The reported metrics include air kerma at the reference point, the kerma-area product, and fluoroscopy time. Dose is reduced by low pulse and frame rates, collimation, keeping the detector close to the patient, limiting steep and magnified views, and avoiding unnecessary cine acquisitions. Operator protection depends on distance, shielding, and time. Dose metrics, skin injury, and operator protection in the catheterization laboratory are on the catheterization laboratory radiation safety hub, and general radiation safety principles are on the radiation safety hub.

Contrast volume is the modifiable determinant of contrast-associated kidney injury. Biplane imaging, fewer and targeted injections, small catheters, and physiology or intravascular ultrasound in place of repeated contrast runs reduce volume (contrast-sparing technique).

Complications of diagnostic catheterization

Serious complications of diagnostic angiography are uncommon and are concentrated in patients with acute coronary syndromes, shock, left main disease, severe aortic stenosis, advanced kidney disease, and peripheral arterial disease. The DISCHARGE invasive arm, which included the PCI and surgery that followed angiography, recorded major procedure-related complications in 1.9% of patients.

Catheter-induced coronary and aortic dissection. In a 21-year series of 76,104 diagnostic and therapeutic procedures, catheter-induced coronary or aortic dissection occurred in 0.126% and aortic injury in 0.021%; in-hospital mortality was 4.2% overall and 6.25% with aortic dissection. Patients with dissection were more often women and more often had hypertension, chronic kidney disease, acute myocardial infarction, and PCI. Predisposing factors were a small ostium or ostial atheroma. Precipitating factors were deep intubation, catheter malalignment, and probing of the vessel. Wedged contrast injection was the most common mechanism and the only mechanism of aortic dissection. The dissection propagated in 30.2%, most often after repeated injections through an unchanged catheter.

Cholesterol embolization. In a prospective study of 1,786 patients aged 40 years or older undergoing left heart catheterization, cholesterol embolization syndrome developed in 1.4%, manifested by livedo reticularis, blue toes, or digital gangrene (48% of cases) and kidney dysfunction (64%). Patients with the syndrome had higher eosinophil counts and an in-hospital mortality of 16.0%, compared with 0.5% in patients without it. Femoral access did not increase the incidence, which implicates the ascending aorta as a source, and an elevated preprocedural C-reactive protein was the only independent predictor.

ComplicationRecognitionImmediate response
Vasovagal reactionBradycardia, hypotension, pallor, nausea, often with sheath insertion or painAtropine, volume, leg elevation; exclusion of bleeding and tamponade
Ventricular arrhythmiaVentricular fibrillation with a wedged catheter or contrast in the conus or a small right coronary arteryDefibrillation; catheter repositioned before further injection
Air embolismAbrupt filling defect, slow flow, ischemia after injectionOxygen, aspiration through the catheter, hemodynamic support; prevented by meticulous flushing
Catheter-induced dissectionContrast staining at the ostium, often with pressure dampingCatheter withdrawn; stent to seal the entry when flow is compromised; repeated injection avoided
Catheter-induced spasmSmooth ostial or proximal narrowing that reverses with intracoronary nitroglycerinNitroglycerin and catheter repositioning
StrokeFocal deficit during or after the studyStroke team activation and imaging
Retroperitoneal hemorrhageHypotension, back or flank pain after femoral puncture, often without a visible hematomaVolume and transfusion, anticoagulant reversal, CT, endovascular control when bleeding persists
PseudoaneurysmPulsatile mass with bruitDuplex ultrasound; ultrasound-guided thrombin injection or compression; covered stent or surgical repair when these fail
Arteriovenous fistulaContinuous bruit and thrillDuplex ultrasound; observation, since 38% of femoral fistulas closed spontaneously within 12 months in a prospective series; covered stent or surgical repair for a persistent symptomatic fistula
Radial artery occlusion or spasmAbsent radial pulse; pain and catheter resistanceVasodilators for spasm; heparin and patent hemostasis prevent occlusion
Cholesterol embolizationLivedo, blue toes, eosinophilia, kidney injury days to weeks laterSupportive care
Contrast reaction or kidney injuryUrticaria to anaphylaxis; rising creatinineContrast hub

Complications of diagnostic catheterization and their recognition.

Left heart catheterization: ventricular pressure and LVEDP

A pigtail or multipurpose catheter is advanced retrogradely across the aortic valve into the left ventricle. The left ventricular pressure tracing shows a systolic peak equal to aortic systolic pressure in the absence of outflow obstruction, a rapid fall to an early diastolic minimum, slow filling, the a wave of atrial contraction, and the end-diastolic pressure at the onset of systole.

Left ventricular end-diastolic pressure (LVEDP) is measured at the end of the a wave, just before the upstroke of ventricular systole, at end-expiration; a normal value is 12 mm Hg or less. An elevated LVEDP reflects volume overload, reduced compliance, or both, and the measurement is made before contrast, which raises filling pressure. LVEDP measured with a simultaneous wedge pressure distinguishes left ventricular from left atrial and pulmonary venous disease (wedge and LVEDP).

A pullback from the left ventricle to the aorta detects a gradient. A systolic gradient that appears within the ventricular cavity, before the catheter crosses the valve, locates the obstruction in the outflow tract, as in hypertrophic cardiomyopathy; a gradient at the valve plane is valvular. Valve gradients are measured with simultaneous left ventricular and ascending aortic pressures; femoral sheath pressure overstates aortic systolic pressure because of peripheral amplification. Retrograde crossing of a severely stenotic aortic valve carries a small risk of cerebral embolism. The Gorlin and Hakki calculations are on the aortic stenosis hub.

Combined right and left heart catheterization measures right-sided pressures, cardiac output, saturations, and resistances in the same session and is performed before contrast is given. Its indications include heart failure with uncertain filling pressures, pulmonary hypertension, valve disease with discordant noninvasive data, constrictive and restrictive physiology, and shunts (right heart catheterization).

Aortic pressure damping and ventricularization

The pressure at the catheter tip is monitored throughout coronary engagement. Damping is a fall in the amplitude of the whole waveform with a lower systolic pressure and a blunted dicrotic notch. Ventricularization is the specific loss of the diastolic aortic contour: diastolic pressure falls during diastole and the trace resembles a ventricular pressure curve. The catheter tip is isolated distal to an obstruction and records pressure in a vessel draining into the myocardium. Both appear when the catheter occludes the ostium because of ostial stenosis, spasm, a small vessel, or deep seating.

Injection into a damped catheter can dissect the ostium, propagate a dissection into the aortic root, or cause ischemia and ventricular fibrillation. The catheter is withdrawn, a nonselective cusp injection defines the ostium, and ostial left main or right coronary disease is suspected when damping recurs with careful coaxial engagement. During pressure-wire measurement, damping lowers the aortic reference pressure and falsely raises the ratio.

Left ventriculography: technique, wall motion, and mitral regurgitation

Contrast ventriculography injects a bolus through a pigtail catheter in the mid ventricle, away from the mitral apparatus, with a power injector. The right anterior oblique view shows the anterobasal, anterolateral, apical, inferior, and posterobasal walls and the mitral valve in profile; the left anterior oblique view shows the septum, the posterolateral wall, and the left ventricular outflow tract. End-diastolic and end-systolic silhouettes are traced to calculate volumes and ejection fraction by the area-length method. Regional wall motion is described as normal, hypokinetic, akinetic, dyskinetic (paradoxical systolic bulging), or aneurysmal. Ventriculography also shows left ventricular thrombus, apical ballooning in takotsubo syndrome, a ventricular septal rupture, and outflow obstruction.

Mitral regurgitation is graded semiquantitatively from 1+ to 4+ by the density and clearance of contrast in the left atrium compared with the ventricle; grades 1+ and 2+ correspond to progressive regurgitation and grades 3+ and 4+ to severe regurgitation in the 2020 ACC/AHA valve guideline. Catheter position, injection rate, ectopy, and atrial size affect the grade, and catheter-induced premature beats create spurious regurgitation. The grading definitions and their limitations are on the mitral regurgitation hub.

Ventriculography adds contrast and is omitted when echocardiography has defined ventricular function, when kidney function is reduced, when LVEDP is markedly elevated, and when left ventricular thrombus or severe aortic stenosis makes crossing hazardous.

Coronary anatomy and branches

The left main coronary artery arises from the left sinus of Valsalva, runs behind the pulmonary trunk, and divides into the left anterior descending (LAD) and circumflex arteries; in some hearts a third branch, the ramus intermedius, arises between them. The LAD runs in the anterior interventricular groove to the apex and often wraps around it to the inferior apex. Its septal perforators supply the anterior two-thirds of the septum and its diagonal branches the anterolateral wall. The circumflex runs in the left atrioventricular groove and gives obtuse marginal branches to the lateral wall; in left dominance it continues to the posterior descending and posterolateral branches.

The right coronary artery arises from the right sinus and runs in the right atrioventricular groove. Its first branch is usually the conus artery, which arises from a separate ostium in some hearts. The sinoatrial nodal artery follows in most hearts, then right ventricular branches and the acute marginal artery, and, in right dominance, the posterior descending artery, the atrioventricular nodal artery, and posterolateral branches. Coronary anatomy as it localizes an acute infarct is reviewed on the STEMI hub.

ArteryCourseBranchesTerritory
Left mainLeft sinus, behind the pulmonary trunk, to its bifurcation or trifurcationLAD, circumflex, ramus intermediusMost of the left ventricle in right dominance; all of it in left dominance
LADAnterior interventricular groove to the apexSeptal perforators, diagonalsAnterior wall, anterior septum, apex
CircumflexLeft atrioventricular grooveObtuse marginals; posterior descending and posterolateral branches in left dominanceLateral wall; inferior wall when dominant
Right coronaryRight atrioventricular grooveConus, sinoatrial nodal, right ventricular, acute marginal, posterior descending, atrioventricular nodal, posterolateralRight ventricle, inferior wall, inferior septum, nodes
Ramus intermediusFrom a trifurcating left main between LAD and circumflexNone namedHigh lateral wall

Coronary arteries, branches, and myocardial territories.

Coronary dominance

Dominance is defined by the artery that gives rise to the posterior descending artery and the posterolateral branches. In a postmortem angiographic series of 1,453 hearts, 81.2% were right dominant, 9.1% left dominant, and 9.7% codominant, and left and codominant patterns became less common with increasing age. In 4,000 angiograms from South India, the proportions were 85.5%, 9.7%, and 4.8%. Dominance determines which artery supplies the inferior wall, the inferior septum, and usually the atrioventricular node.

In left dominance, the right coronary artery is small and ends before the crux; a small right coronary artery is then a normal variant, and the inferior wall depends on the circumflex. A circumflex occlusion in a left-dominant heart causes inferior infarction with atrioventricular block, an ECG pattern otherwise attributed to the right coronary artery. In a left-dominant system, the left main supplies the entire left ventricle, so left main disease jeopardizes more myocardium. A codominant pattern has posterior descending branches or posterolateral branches from both arteries.

Segment nomenclature: AHA, SCCT, and SYNTAX segment models

The AHA coronary segment model numbered the coronary tree so that lesions are located reproducibly. The Society of Cardiovascular Computed Tomography (SCCT) extended it to 18 segments for CT, and the SYNTAX score uses a related model in which segment weights depend on dominance. The right coronary artery is divided into proximal, mid, and distal segments by the acute margin and the crux. The LAD is divided into proximal (to the first major septal or diagonal branch), mid, and distal segments, and the circumflex into proximal and mid-distal segments around the first obtuse marginal branch. The SCCT segment numbers and boundaries are tabulated on the coronary CT angiography hub. Using one model in angiographic, CT, and surgical reports allows a lesion to be tracked across modalities and over time.

The SYNTAX score sums points for all lesions with 50% or more stenosis in vessels of 1.5 mm or more, weighted for location and adverse features; scores of 22 or less, 23 to 32, and 33 or more define low, intermediate, and high anatomic complexity (SYNTAX and SYNTAX II).

Standard angiographic projections and the segments they show

Projections are named for the position of the image intensifier or flat-panel detector relative to the patient. Right anterior oblique (RAO) and left anterior oblique (LAO) describe rotation of the detector to the patient's right or left; cranial and caudal describe tilt of the detector toward the head or the feet. In the RAO projection the spine is on the right of the image and the heart on the left; in the LAO projection the spine is on the left. Cranial angulation opens structures that run toward the apex and diaphragm (mid and distal LAD, diagonal bifurcations, the crux). Caudal angulation opens basal structures (left main, proximal circumflex, obtuse marginals). No single projection shows a segment free of overlap and foreshortening, so a lesion is recorded in at least two substantially different projections.

ProjectionArterySegments best shown
Anteroposterior or shallow RAO caudalLeftLeft main body and bifurcation, proximal LAD and circumflex
RAO caudalLeftProximal circumflex, obtuse marginals, proximal LAD
RAO cranialLeftMid and distal LAD with septal branches separated from diagonals
Anteroposterior cranialLeftMid LAD and diagonal origins
LAO cranialLeftMid and distal LAD, diagonal bifurcations, ostial left main
LAO caudal ("spider" view)LeftLeft main, LAD and circumflex origins, proximal circumflex
Left lateralLeftMid LAD, circumflex; internal mammary to LAD anastomosis
LAORightProximal and mid right coronary artery
LAO cranialRightDistal right coronary artery, crux, posterior descending and posterolateral origins
RAORightMid right coronary artery and the length of the posterior descending artery
Anteroposterior cranialRightPosterior descending and posterolateral branches

Standard projections by artery. Angulation is adjusted to the patient's anatomy; the projections that separate a lesion are recorded in the report.

Foreshortening, overlap, and other sources of error in angiographic interpretation

Angiography is a two-dimensional projection of a three-dimensional lumen. Foreshortening occurs when a segment runs toward or away from the detector: it appears short and can hide a stenosis or make a long lesion look focal. Overlap of branches, the spine, catheters, or other vessels can create or conceal a stenosis, particularly at bifurcations. Eccentric lesions look severe in one projection and mild in the orthogonal one; the worst projection represents the minimal lumen.

Underfilling from inadequate contrast injection, competitive flow from a collateral or graft, or streaming produces apparent filling defects and haziness. Ostial lesions are misjudged when the catheter tip sits beyond the ostium or when contrast refluxes into the sinus.

Diffuse disease narrows the reference segment so that the percentage stenosis underestimates the true narrowing, and positive remodeling hides plaque behind an apparently normal lumen. Spasm, catheter-induced or spontaneous, mimics fixed disease until intracoronary nitroglycerin is given. Myocardial bridging compresses a segment in systole, and the segment returns to normal caliber in diastole. Motion and low frame rate blur small vessels.

Visual stenosis grading and quantitative coronary angiography

Stenosis severity is reported as percentage diameter reduction relative to an adjacent normal-appearing reference segment, in the projection that shows the minimal lumen. Visual grading is categorical: luminal irregularities, mild narrowing, moderate (intermediate) stenosis, severe stenosis, subtotal occlusion, and total occlusion. A diameter stenosis of 50% or more is the conventional threshold for obstructive disease in the left main, and 70% or more in the other epicardial arteries. Intermediate lesions in the range of about 40% to 70% are those in which physiology most often changes the decision. Diameter reduction does not equal hemodynamic significance, because the pressure loss across a stenosis depends on lesion length, entrance and exit angles, minimal lumen area, the myocardial mass supplied, collateral flow, and the microcirculation.

Quantitative coronary angiography

Quantitative coronary angiography (QCA) uses edge-detection software, calibrated against the catheter of known diameter or by isocenter calibration, to measure minimal lumen diameter, reference diameter, percentage diameter stenosis, and lesion length. It reduces the interobserver variability of visual grading and is the standard measurement for restenosis and late lumen loss in trials. Its limits are those of the projection: foreshortening, overlap, calibration error, and eccentric lesions. Three-dimensional QCA reconstructs the vessel from two projections and is the basis of angiography-derived FFR (angiography-derived FFR).

Interobserver variability and the mismatch between anatomy and physiology

Visual estimates of stenosis differ between readers, with the greatest disagreement in intermediate lesions, and they tend to overestimate severity compared with QCA. The physiologic mismatch is larger. In the FFR arm of FAME, 1,329 lesions were measured after visual grading. Of lesions graded 50% to 70%, 35% had an FFR of 0.80 or less. Of lesions graded 71% to 90%, 80% were functionally significant, as were 96% of subtotal stenoses. Only 235 of 509 patients (46%) with angiographic multivessel disease had functional multivessel disease. These data underlie the use of physiology for intermediate and multivessel disease (physiology).

Lesion morphology: ACC/AHA lesion types, calcification, bifurcations, and total occlusions

The ACC/AHA lesion classification grouped target stenoses as type A, B, or C by features that predicted the success and complications of balloon angioplasty, including length, eccentricity, tortuosity, angulation, calcification, ostial location, bifurcation involvement, thrombus, and total occlusion. In the Multivessel Angioplasty Prognosis Study (350 patients, 1,100 stenoses), type B was divided into B1 (one type B characteristic) and B2 (two or more). Success and major complication rates per stenosis were 92% and 2% for type A, 84% and 4% for B1, 76% and 10% for B2, and 61% and 21% for type C. Chronic total occlusion, high-grade 80% to 99% stenosis, a bend of more than 60 degrees, and excessive tortuosity were particularly predictive of an adverse result. The classification describes procedural complexity in the balloon era and is a descriptive vocabulary in the stent era; SYNTAX, intravascular imaging, and physiology now carry the decisions.

Calcification. Calcium appears on fluoroscopy before contrast injection as radiopaque densities along the vessel wall, and angiography underestimates its extent. Its arc, thickness, and depth, which decide the need for atherectomy or lithotripsy before stenting, are measured by intravascular imaging.

Bifurcation lesions. A bifurcation lesion is a narrowing adjacent to or involving the origin of a significant side branch. The Medina classification assigns 1 or 0 to three segments in the order proximal main vessel, distal main vessel, and side branch, with 1 indicating stenosis of more than 50%; a 1,1,1 lesion involves all three segments and a 0,0,1 lesion only the side branch. Bifurcation angles are measured with dedicated angiographic views, three-dimensional angiography, or CT.

Total occlusion. An acute thrombotic occlusion shows an abrupt or convex cutoff, often with a hazy filling defect, and usually no established collaterals. A chronic total occlusion shows a tapered or blunt stump, calcification, bridging collaterals across the occluded segment, and a distal bed filled from collaterals. These are clues to timing: collaterals can predate an acute occlusion, and the clinical history or a prior angiogram establishes chronicity.

Thrombus on angiography and the TIMI thrombus grade

Thrombus appears as an intraluminal filling defect surrounded by contrast in more than one projection, with hazy margins, contrast staining, or a convex meniscus at an occlusion. It is distinguished from calcium by its lack of density before contrast, from dissection by the absence of a linear flap, and from an ostial streaming artifact by its persistence.

The TIMI thrombus grade, used in the TIMI 4, 10A, 10B, and 14 angiographic analyses, describes thrombus burden by its size relative to the vessel diameter. In those analyses, angiographically evident thrombus was less frequent after combination therapy with abciximab (26.6% vs 35.4%), and its absence was associated with more frequent early ST-segment resolution.

In 812 patients treated with drug-eluting stents for STEMI, a large thrombus burden of 2 vessel diameters or more independently predicted major adverse cardiac events (hazard ratio 1.88) and infarct-related artery stent thrombosis (8.2% vs 1.3% at 2 years). In a series of 900 patients with STEMI, 57.7% presented with a grade 5 occlusion. After flow was restored with a guidewire or a 1.5-mm balloon, the thrombus was regraded in 97.9% of them. Large thrombus (grade 4) independently predicted 2-year mortality (hazard ratio 1.66).

GradeDefinition
0No angiographic thrombus
1Possible thrombus
2Small thrombus, greatest dimension half the vessel diameter or less
3Moderate thrombus, greatest dimension more than half and less than 2 vessel diameters
4Large thrombus, greatest dimension 2 vessel diameters or more
5Total occlusion; thrombus burden cannot be assessed

TIMI thrombus grade (Gibson 2001), with grade boundaries as defined by Sianos 2010; large-thrombus threshold of 2 vessel diameters after Sianos 2007. Grade 4 denotes large thrombus. In grade 5 the occlusion conceals the thrombus, which is regraded after flow is restored with a guidewire or a small balloon.

Left coronary angiogram in a patient with ST-elevation myocardial infarction; an arrow marks an abrupt narrowing of the circumflex artery, and an asterisk marks the tip of a guidewire that has crossed the lesion into the distal vessel.
Left coronary angiogram during primary PCI for ST-elevation myocardial infarction. The arrow marks a partial occlusion of the circumflex artery with reduced distal opacification; the guidewire has crossed the lesion and its tip (asterisk) lies in the distal vessel. Credit: Todt T, Maret E, Alfredsson J, Janzon M, Engvall J, Swahn E, BMC Cardiovasc Disord 2012;12:9, via Wikimedia Commons, CC BY 2.0.

TIMI flow grade and corrected TIMI frame count

The TIMI flow grade, introduced in the phase I TIMI trial, grades antegrade epicardial flow on a 4-point scale. Grade 0 is no flow beyond the occlusion. Grade 1 is minimal flow: contrast passes the obstruction without opacifying the whole distal bed. Grade 2 is partial perfusion: the distal bed opacifies, with filling or clearance slower than in a normal artery. Grade 3 is complete perfusion with normal filling and clearance.

Grades 0 and 1 were originally counted as thrombolysis failure and grades 2 and 3 as success. An artery with TIMI 2 flow, however, behaves like an occluded artery. In TEAM-3, patients with grade 2 flow did not differ from those with grade 0 or 1 in ejection fraction, enzyme release, or ECG indexes, whereas patients with grade 3 flow had higher global and infarct-zone ejection fractions. In a meta-analysis of 3,969 patients from 5 thrombolysis studies (Anderson 1996), early mortality was 8.8% with grade 0 or 1 flow, 7.0% with grade 2, and 3.7% with grade 3. TIMI 3 flow is therefore the reperfusion target.

The TIMI flow grade is subjective and categorical. The TIMI frame count is the number of cine frames needed for contrast to reach a standardized distal landmark in the artery. In 78 normal arteries, the LAD count (36.2 ± 2.6 frames) was 1.7 times the mean of the circumflex (22.2 ± 4.1) and right coronary (20.4 ± 3.0) counts, so the LAD count is divided by 1.7 to give the corrected TIMI frame count. The count was reproducible (mean absolute difference between injections 4.7 ± 3.9 frames). In culprit arteries 90 minutes after thrombolysis, the corrected count averaged 39.2 ± 20.0 frames and followed a continuous distribution. Nonculprit arteries also had slower flow than normal arteries in the first hours, which implicates microvascular resistance. The frame count depends on the cine frame rate, and the normal values apply to the acquisition rate used in the original series.

Slow flow and no-reflow. No-reflow is slow epicardial flow in a patent artery without residual obstruction after reperfusion or PCI, caused by distal embolization, microvascular obstruction, and edema. It is recognized by TIMI flow below 3 or a prolonged frame count with poor myocardial blush. It is treated with microvascular vasodilators and support of perfusion pressure; nitroglycerin acts on epicardial vessels and does not reverse it. The coronary slow-flow phenomenon in arteries without obstruction is a form of microvascular dysfunction.

The same left coronary angiogram after primary PCI, showing a widely patent circumflex artery with brisk opacification of its distal branches.
The same patient after primary PCI of the circumflex artery. The treated segment is no longer narrowed and the distal branches opacify fully, consistent with restored epicardial flow; tissue-level perfusion is graded separately by myocardial blush. Credit: Todt T, Maret E, Alfredsson J, Janzon M, Engvall J, Swahn E, BMC Cardiovasc Disord 2012;12:9, via Wikimedia Commons, CC BY 2.0.

Myocardial blush grade and TIMI myocardial perfusion grade

An open epicardial artery does not guarantee perfused myocardium. Tissue perfusion is graded from the ground-glass opacification ("blush") of the myocardium supplied by the artery during the late phase of a long cine run.

The myocardial blush grade was described in 777 patients after primary angioplasty: grade 0, no blush; grade 1, minimal blush; grade 2, moderate blush; and grade 3, normal blush. Blush grade tracked ST-segment resolution, enzymatic infarct size (757, 1,143, and 1,623 units for grades 3, 2, and 0 or 1), and ejection fraction (50%, 46%, and 39%). Over a mean follow-up of 1.9 years, mortality was 3%, 6%, and 23% for grades 3, 2, and 0 or 1, and blush grade predicted mortality independently of TIMI flow, Killip class, and ejection fraction.

The TIMI myocardial perfusion (TMP) grade, developed in TIMI 10B (762 patients), grades both entry and clearance of contrast from the microvasculature. Grade 0 is no tissue-level perfusion, and grade 1 is blush that does not clear and is still present on the next injection. Grade 2 is blush that clears slowly, strongly persistent and diminishing minimally or not at all during 3 cardiac cycles of washout; grade 3 is blush that begins to clear during washout and is minimally persistent after 3 cardiac cycles. Thirty-day mortality was 2.0%, 4.4%, and 6.0% with TMP grades 3, 2, and 0 or 1. Among patients with TIMI 3 epicardial flow, mortality was 0.73% with TMP grade 3, 2.9% with grade 2, and 5.0% with grade 0 or 1. The numbering of the two scales differs at grade 1: blush grade 1 is minimal blush, and TMP grade 1 is blush without clearance.

GradeTIMI flowBlush gradeTMP grade
0No flow beyond the occlusionNo blushNo tissue-level opacification
1Minimal flow; distal bed not fully opacifiedMinimal blushBlush present that does not clear by the next injection
2Partial perfusion; slow filling or clearanceModerate blushBlush that clears slowly, strongly persistent after 3 cycles of washout
3Complete perfusion; normal filling and clearanceNormal blushBlush that begins to clear during washout, minimally persistent after 3 cycles
Outcome gradientEarly mortality 8.8% (0 or 1), 7.0% (2), 3.7% (3) in pooled thrombolysis studiesMortality 23% (0 or 1), 6% (2), 3% (3) at 1.9 years after primary angioplasty30-day mortality 6.0% (0 or 1), 4.4% (2), 2.0% (3) after thrombolysis

Epicardial and tissue-level reperfusion grades (TIMI Study Group 1985; Anderson 1993; Anderson 1996; van 't Hof 1998; Gibson 2000).

Angiographic grading aid

The aid assembles TIMI flow, the corrected TIMI frame count, myocardial blush, thrombus burden, and dissection type into a structured description, using the definitions above.

TIMI flow, frame count, blush, thrombus, and dissection grade

Adult coronary angiography
Corrected TIMI frame count—
Normal mean ± SD for this artery—
—

Corrected TIMI frame count = frames to the distal landmark, divided by 1.7 for the LAD; normal values 36.2 ± 2.6 frames for the LAD (21.3 ± 1.5 corrected), 22.2 ± 4.1 for the circumflex, and 20.4 ± 3.0 for the right coronary artery (Gibson 1996). Blush grade after van 't Hof 1998; thrombus grade after Gibson 2001 and Sianos 2010; dissection types after Huber 1991.

Collateral circulation: Rentrop and collateral connection grades

Collaterals are preexisting interarterial connections that enlarge when a stenosis creates a sustained pressure gradient. They appear as filling of the distal bed of an occluded artery from the same artery (bridging or ipsilateral collaterals) or from another artery (contralateral collaterals, such as septal channels from the LAD to the posterior descending artery or epicardial channels across the apex or the atrioventricular grooves). Contralateral collaterals are shown by injecting the donor artery with a long cine run, and simultaneous injection of both arteries defines the occluded segment before chronic total occlusion PCI.

The Rentrop grade was defined during balloon occlusion of the LAD or right coronary artery with contralateral injection: grade 0, no filling of collateral channels; grade 1, filling of side branches of the occluded artery without visualization of the epicardial segment; grade 2, partial filling of the epicardial segment; and grade 3, complete filling of the epicardial segment. In the original 16 patients, collateral filling improved by one to three grades within seconds of balloon occlusion in all but one, showing that collaterals are recruited acutely and that the grade depends on the pressure gradient at the time of injection.

The collateral connection (CC) grade describes the channel itself: CC0, no continuous connection between donor and recipient; CC1, a threadlike continuous connection; and CC2, a continuous side-branch-like connection. In 100 patients with chronic total occlusion, the CC grade, unlike the Rentrop grade or the anatomic location, was independently related to invasively measured collateral resistance. CC2 collaterals preserved regional left ventricular function better and provided higher collateral flow reserve than CC1, and CC0 channels predominated in recent occlusions of 2 to 4 weeks. The CC grade is used in chronic total occlusion PCI to select collateral channels for the retrograde approach.

GradeRentrop (recipient filling)Collateral connection (channel size)
0No collateral fillingNo continuous connection
1Side branches of the occluded artery fill; epicardial segment not seenThreadlike continuous connection
2Partial filling of the epicardial segmentSide-branch-like continuous connection
3Complete filling of the epicardial segmentNot defined

Collateral grading (Rentrop 1985; Werner 2003). The Rentrop grade describes how much of the recipient artery fills; the collateral connection grade describes the size of the channel and relates to collateral function.

Coronary dissection on angiography: NHLBI types A to F

The National Heart, Lung, and Blood Institute (NHLBI) classification grades dissection caused by balloon angioplasty, catheters, and wires by its angiographic morphology. In 691 dissections after angioplasty, type B dissections (543 patients) did not increase morbidity or mortality, with a success rate of 93.7%. Types C to F (148 procedures) were associated with acute closure in 31%, emergency bypass surgery in 37%, myocardial infarction in 13%, and repeat angioplasty in 24%, and clinical success was 38%. Types A and B are generally managed conservatively or are covered by the stent being placed; types C to F after PCI are sealed with a stent when flow is threatened.

TypeAngiographic appearanceUsual significance
ALuminal haziness or minor radiolucent areas within the lumen during contrast injection, with no persistence after dye clearance and no flow impairmentBenign
BParallel tracts or double lumen separated by a radiolucent area during injection, with minimal or no persistence after clearance and no flow impairmentBenign in balloon angioplasty series
CExtraluminal cap with persistence of contrast after dye clearance from the lumenHigh risk of closure
DSpiral ("barber pole") luminal filling defects, usually with excessive and persistent staining of the false lumen and often delayed antegrade flowHigh risk
ENew, persistent filling defects within the lumenHigh risk; may represent thrombus
FNon A–E types that lead to impaired flow or total occlusionThreatened or established closure

NHLBI coronary dissection classification (definitions as tabulated by Klaudel 2024; outcomes from Huber 1991).

Spontaneous coronary artery dissection (SCAD) has its own angiographic classification (types 1, 2A, 2B, 3, and 4), which describes intramural hematoma and false lumens in a vessel without iatrogenic injury. Its angiographic diagnosis and the risk of iatrogenic extension during angiography are covered on the SCAD hub. Catheter-induced dissection, its incidence, and its mechanisms are described under complications.

Coronary perforation: the Ellis classification

Perforation is a complication of PCI, most often from wires, oversized balloons or stents, and atheroablative devices. In the registry that defined the classification, perforation occurred in 0.5% of 12,900 procedures, more often with atherectomy and laser devices than with balloon angioplasty (1.3% vs 0.1%).

Class I is an extraluminal crater without extravasation; class II is pericardial or myocardial blushing without a jet; class III is a perforation of 1 mm or more with contrast streaming; and cavity spilling is perforation into a cardiac chamber or the coronary sinus. Tamponade occurred in 8% of class I, 13% of class II, and 63% of noncavity class III perforations, and death in 0%, 0%, and 19%. Two of 15 tamponades were delayed, which is the basis for observation for at least 24 hours after a perforation. Treatment includes balloon tamponade, reversal of anticoagulation, covered stents, coil or fat embolization, and pericardiocentesis. Sealing techniques and late tamponade are covered on the PCI complications hub.

Spasm, myocardial bridging, ectasia, anomalies, and fistulas

Spasm. Catheter-induced spasm is a smooth concentric narrowing at or just beyond the catheter tip, most often in the proximal right coronary artery, that resolves after intracoronary nitroglycerin and catheter withdrawal. A lesion first seen at the ostium is reinjected after nitroglycerin before it is graded. Spontaneous spasm and provocation testing with acetylcholine are covered on the vasospastic angina hub. Catheter-induced dissection can mimic spasm and does not resolve with nitroglycerin.

Myocardial bridging. A bridged segment, usually the mid LAD, is compressed in systole and returns to normal or near-normal caliber in diastole (the milking effect). In 5,525 consecutive diagnostic angiograms with routine intracoronary nitroglycerin, bridging was present in 16.1%. Nitroglycerin increased systolic compression (from 43% to 54%) and the apparent length of the bridge, and atherosclerosis was more common proximal to the bridge (40.3%) than distal to it (5.5%). Because coronary flow is predominantly diastolic, most bridges are benign; symptomatic bridging is treated with beta-blockade, which lengthens diastole.

Ectasia and aneurysm. Coronary ectasia is diffuse dilation of a long segment, and an aneurysm is a focal dilation, both relative to the adjacent normal segment. Sluggish flow, contrast stasis, and layered thrombus occur in ectatic arteries. In the Coronary Artery Surgery Study registry, 4.9% of patients had aneurysmal coronary disease, with risk factors and 5-year survival similar to those of other patients with coronary disease. Most cases are therefore a variant of atherosclerosis. Kawasaki disease, connective tissue disease, mycotic infection, and stent-related aneurysm are less common causes.

Anomalous origin and course. An absent ostium in the expected sinus, a vessel arising from the opposite sinus or from another coronary artery, or an unexpected initial course indicates an anomaly. Invasive angiography shows the origin but defines the three-dimensional course poorly. High-risk features (an interarterial course between the aorta and pulmonary artery, an intramural segment, a slit-like ostium, and acute angle takeoff) are defined by CT or MR angiography (coronary anomalies on CT). Separate ostia of the LAD and circumflex without a left main, and an anomalous circumflex from the right sinus or right coronary artery coursing behind the aorta, are benign variants that change catheter selection.

Fistulas. A coronary artery fistula is an enlarged, tortuous artery that drains into a cardiac chamber, the coronary sinus, or the pulmonary artery, with rapid washout at the drainage site. Most drain into right-sided structures; large fistulas cause a continuous murmur, coronary steal, and volume overload.

Bypass graft angiography and graft failure

Graft angiography begins with the operative report, which states the number of grafts, their origins and targets, and any radiopaque ostial markers. Saphenous vein grafts to the left coronary territory arise from the anterior ascending aorta above the right graft origins, and grafts to the right coronary artery arise lower and more rightward; they are engaged with Judkins right, Amplatz, multipurpose, or dedicated bypass catheters. The left internal mammary artery is engaged from the left subclavian artery with an internal mammary catheter, usually from left radial or femoral access; a right internal mammary artery from the right subclavian. A radial artery graft arises from the aorta like a vein graft and is prone to spasm. When a graft cannot be found, nonselective aortography with a pigtail catheter in the ascending aorta shows the patent graft origins. A graft that does not opacify on aortography and has no stump is considered occluded only after the native circulation has been injected to show which territories fill.

Graft failure has a characteristic time course. Early failure (within the first month) reflects technical error or thrombosis; failure in the first year reflects intimal hyperplasia, often at anastomoses. Later failure of vein grafts reflects atherosclerosis, seen as diffuse irregularity, ectasia, and friable plaque prone to distal embolization during intervention. An occluded vein graft appears as a blind stump at the aortic ostium. Internal mammary artery grafts to the LAD are typically smooth and remain patent for decades; competitive flow from a native artery with only moderate stenosis can cause a mammary graft to become thin or string-like. Subclavian stenosis proximal to a mammary graft causes ischemia in the grafted territory. Patency rates by conduit are on the cardiac surgery hub.

Native arteries are imaged fully in patients with grafts, because native disease progresses proximal to the anastomoses and PCI of the native artery is preferred over PCI of a degenerated vein graft when feasible. The 2021 revascularization guideline downgraded embolic protection devices for vein graft PCI from Class 1 to Class 2a.

Stents on angiography

Stent struts are visible on fluoroscopy and define the stented segment. A patent stent fills to the reference diameter; in-stent restenosis is narrowing within the struts with preserved through-flow; stent thrombosis is a filling defect or abrupt cutoff at the stent; and edge disease lies at or just beyond the stent margins. Underexpansion, malapposition, and fracture are recognized reliably only with intravascular imaging or enhanced stent visualization.

Intravascular imaging and left main assessment in outline

Intravascular ultrasound (IVUS) and optical coherence tomography (OCT) image the vessel wall in cross-section and answer questions that the lumen silhouette cannot: true vessel size, plaque burden, calcium arc and thickness, thrombus, dissection, stent expansion and apposition, and the mechanism of stent failure. In the 2021 ACC/AHA/SCAI guideline, IVUS can be useful for procedural guidance, particularly in left main or complex stenting (Class 2a). OCT is a reasonable alternative except in ostial left main disease (Class 2a), and IVUS or OCT is reasonable to determine the mechanism of stent failure (Class 2a) (intravascular imaging in chronic coronary disease). Image acquisition, measurements, and stent optimization criteria are on the intravascular imaging hub.

For an angiographically intermediate left main stenosis, the multicenter LITRO study applied an IVUS minimal lumen area of 6 mm² as the threshold for revascularization in 354 patients. Revascularization was deferred in 96% of patients with an area of 6 mm² or more, and 2-year cardiac death-free survival was 97.7% in the deferred group and 94.5% in the revascularized group; only 4.4% of deferred patients needed later left main revascularization. Smaller thresholds derived in other populations are applied with physiology and clinical context.

Fractional flow reserve: principle and threshold

Fractional flow reserve (FFR) is the ratio of maximal flow in a stenotic artery to the maximal flow the same artery would carry without the stenosis. During maximal hyperemia, when microvascular resistance is minimal and assumed constant, flow is proportional to perfusion pressure, so FFR is measured as mean distal coronary pressure (Pd) divided by mean aortic pressure (Pa). A normal artery has an FFR close to 1.0. FFR is specific to the epicardial vessel, accounts for the myocardial mass supplied and for collateral flow, and is largely independent of heart rate and blood pressure.

The clinical threshold is 0.80 or less. DEFER used 0.75; values between 0.75 and 0.80 are the gray zone, in which ischemia is possible and the decision weighs symptoms, the territory, and the lesion (invasive FFR as the reference standard). In FAME, 1,005 patients with multivessel disease underwent PCI guided by angiography alone or by FFR with stenting only of lesions with FFR 0.80 or less. The 1-year rate of death, myocardial infarction, or repeat revascularization was 18.3% with angiographic guidance and 13.2% with FFR guidance, and fewer stents were placed with FFR guidance (1.9 vs 2.7 per patient). The treatment decision in chronic coronary disease is summarized on the chronic coronary disease hub.

Measurement uses a coronary pressure guidewire with a sensor near the tip, or a microcatheter with a pressure sensor. With the sensor at the catheter tip, the wire pressure is equalized with the guide catheter pressure. The wire is then advanced distal to the lesion (at least several vessel diameters beyond it, in a straight segment), and hyperemia is induced. FFR is read as the lowest stable ratio during steady-state hyperemia.

Hyperemic agents

Maximal hyperemia is the condition on which FFR depends; submaximal hyperemia raises the measured ratio and underestimates significance. Adenosine acts on A2A receptors in the arteriolar smooth muscle and dilates the microvasculature independently of the endothelium. Its receptor pharmacology, side effects, and contraindications are on the pharmacologic stress hub.

Agent and routeDose in the cited studiesCharacteristics
Adenosine, intravenous infusion140 µg/kg/min, central or large peripheral veinReference method; steady-state hyperemia allows pullback; chest discomfort, dyspnea, and atrioventricular block are common and brief
Adenosine, intracoronary bolus15–80 µg (low dose) or 120–600 µg (high dose) in a meta-analysis of 11 studiesFFR 0.02 higher on average than with intravenous adenosine; same rate of abnormal FFR; fewer adverse effects; brief hyperemia; transient atrioventricular block in the right coronary artery
Regadenoson, intravenous bolus400 µgFFR equal to adenosine in 100 patients; duration of maximal hyperemia variable (10–600 s), which limits pullback
Papaverine, intracoronaryVaries by vesselProlonged hyperemia; QT and QTU prolongation; polymorphic ventricular tachycardia in 2.8% and ventricular fibrillation in 1.7% of 182 patients in one series
Nonhyperemic ratiosNo vasodilatorFree of hyperemia-related error and symptoms; separate threshold

Hyperemic agents for FFR (van Nunen 2015; Rigattieri 2017; Nakayama 2015).

Technique and sources of error in pressure-wire measurement

A pressure ratio is only as valid as the two pressures that make it. The guide catheter must be free of contrast, flushed with saline, and coaxial without damping. The wire pressure is equalized to the aortic pressure with the sensor at the tip of the guide catheter before the lesion is crossed, and the transducer is at the level of the heart. At the end of the measurement the sensor is pulled back to the guide catheter tip; a ratio that no longer reads 1.00 at that point indicates drift, and measurements near the threshold are repeated after re-equalization.

Source of errorEffect on the ratioCorrection
Guide catheter damping or ventricularizationAortic pressure underestimated; ratio falsely highCatheter disengaged during hyperemia; catheter without side holes; smaller catheter
Guide catheter with side holesAortic pressure recorded proximal to the ostium during deep seating; ratio falsely high in ostial diseaseCatheter without side holes; disengagement
Signal driftRatio falsely high or lowDrift check at the end; re-equalization and repeat
Inadequate hyperemiaRatio falsely high; lesion wrongly deferredAdequate dose and route; intravenous infusion confirmed running
Contrast or nitroglycerin effectTransient change in resistanceMeasurement after washout; intracoronary nitroglycerin before measurement to abolish epicardial tone
Wire-induced pseudostenosis (accordion effect) in tortuous vesselsApparent stenosis that disappears when the wire is withdrawnRecognition on angiography with the wire in place
Transducer height mismatchOffset between pressuresEqualization at the same height
Introducer left in the hemostatic valvePressure leak, damped aortic signalIntroducer removed before measurement

Sources of error in pressure-wire physiology and their correction.

Nonhyperemic pressure ratios: iFR, RFR, and dPR

Nonhyperemic pressure ratios (NHPRs) measure Pd/Pa at rest, without a vasodilator. The instantaneous wave-free ratio (iFR) is Pd/Pa during the diastolic wave-free period. In this part of diastole, identified by wave-intensity analysis, microvascular resistance at rest is as low and as stable as the averaged resistance during adenosine hyperemia. In ADVISE (157 stenoses), iFR correlated closely with FFR (r = 0.9), with an area under the receiver operating characteristic curve of 93% for FFR below 0.80. The resting full-cycle ratio (RFR) is the lowest Pd/Pa found anywhere in the cardiac cycle; in 651 recordings it was diagnostically equivalent to iFR (mean bias −0.002). The lowest ratio fell outside diastole in 12.2% of cycles overall and 32.4% in the right coronary artery. Diastolic pressure ratios averaged over the whole of diastole (dPR) or its middle portion were numerically identical to iFR in VERIFY2, with mean differences of 0.006 or less and diagnostic accuracy against FFR of 76% to 77% for all indexes. The iFR threshold and recommendations extend to them.

The threshold for all NHPRs is 0.89 or less. In DEFINE-FLAIR (2,492 patients) and iFR-SWEDEHEART (2,037 patients), iFR-guided revascularization was noninferior to FFR-guided revascularization for death, myocardial infarction, or unplanned revascularization at 1 year (6.8% vs 7.0%, and 6.7% vs 6.1%), with fewer procedural symptoms (3.1% vs 30.8% in DEFINE-FLAIR) and shorter procedures. Revascularization was deferred more often with iFR.

Five-year results. In iFR-SWEDEHEART at 5 years, the composite was 21.5% with iFR and 19.9% with FFR (hazard ratio 1.09), and all-cause death 9.4% and 7.9% (hazard ratio 1.20, not significant). In DEFINE-FLAIR at 5 years, the composite was 21.1% and 18.4% (hazard ratio 1.18; P = .06), and all-cause death was higher with iFR. In patients who underwent revascularization after physiologic assessment, the composite was higher with iFR (24.6% vs 19.2%), whereas outcomes after deferral were similar (17.9% vs 17.5%).

A study-level meta-analysis of the two trials (2,254 iFR and 2,257 FFR patients) found higher 5-year composite events (hazard ratio 1.18) and all-cause mortality (8.3% vs 6.3%; hazard ratio 1.34) with iFR, and equal rates of myocardial infarction and unplanned revascularization. The mortality difference has no established mechanism, and both indexes remain recommended.

FFR and nonhyperemic ratio discordance

FFR and NHPRs agree on the treatment decision in about four-fifths of intermediate lesions and disagree in about one-fifth. Disagreement follows hyperemic flow. In a combined pressure and Doppler registry of 366 vessels, discordance occurred in 14%. Lesions with an abnormal FFR and a normal iFR had hyperemic flow velocity and coronary flow reserve similar to angiographically unobstructed vessels (median coronary flow reserve 2.36). Lesions with a normal FFR and an abnormal iFR had low hyperemic flow and flow reserve similar to concordantly abnormal lesions (median 1.44).

FFR is therefore more often abnormal in large territories with preserved vasodilator capacity, such as the proximal LAD or left main in younger patients. NHPRs are more often abnormal when hyperemic flow is limited, as in diabetes, advanced age, left ventricular hypertrophy, aortic stenosis, and microvascular disease. The two indexes measure pressure loss under different flow conditions. Discordance is resolved with the clinical picture, the size of the territory, noninvasive ischemia testing, coronary flow reserve, or intravascular imaging.

Pullback, serial lesions, and diffuse disease

A distal FFR or NHPR reflects the cumulative pressure loss along the whole vessel and does not localize it. A pullback recording maps where pressure falls. It is made during steady-state intravenous adenosine for FFR, or at rest for an NHPR, which allows a motorized pullback and co-registration with the angiogram. A sharp step identifies a focal lesion that a stent can correct; a gradual decline over a long segment identifies diffuse disease, in which stenting leaves a low ratio and a higher risk of residual angina. The pullback pressure gradient expresses the pattern on a scale from 0 to 1, higher values indicating predominantly focal and lower values predominantly diffuse disease.

In serial stenoses, the lesions interact under hyperemia: flow through one is limited by the other, so the hyperemic pressure drop across either lesion underestimates the drop it would produce if the other were removed. The lesion with the larger step is treated first, and the remaining lesion is remeasured. FFR-guided treatment of diffuse disease that has no focal step is unlikely to improve the ratio.

Outcome trials of physiology-guided revascularization

DEFER enrolled 325 patients scheduled for PCI of an intermediate stenosis without documented ischemia. Those with FFR of 0.75 or more were randomized to deferral (91) or PCI (90), and those with FFR below 0.75 underwent PCI as planned. Event-free survival at 24 months was 89% after deferral and 83% after PCI, and 78% in the reference group with FFR below 0.75. At 15 years, death rates did not differ (33.0% deferral, 31.1% PCI), and myocardial infarction was less frequent in the deferral group (2.2% vs 10.0%), with no late catch-up.

FAME 2 enrolled patients with stable coronary disease considered for PCI. Patients with at least one stenosis with FFR 0.80 or less were randomized to PCI plus medical therapy or medical therapy alone; patients with all FFR values above 0.80 were followed in a registry on medical therapy. Enrollment stopped early after 1,220 patients (888 randomized) because death, myocardial infarction, or urgent revascularization occurred in 4.3% with PCI and 12.7% with medical therapy alone (hazard ratio 0.32), driven by urgent revascularization (1.6% vs 11.1%).

At 5 years the composite was 13.9% vs 27.0% (hazard ratio 0.46), urgent revascularization 6.3% vs 21.1%, death 5.1% vs 5.2%, and myocardial infarction 8.1% vs 12.0% (hazard ratio 0.66; 95% CI 0.43 to 1.00). The registry patients had a 5-year composite of 15.7%, similar to the PCI group.

TrialPopulationComparisonPrimary result
DEFER (2001)325 patients, intermediate stenosis, no documented ischemiaDeferral vs PCI when FFR ≥0.75Event-free survival at 24 months 89% vs 83%; myocardial infarction at 15 years 2.2% vs 10.0%
FAME (2009)1,005 patients, multivessel diseaseFFR-guided (≤0.80) vs angiography-guided PCIDeath, MI, or repeat revascularization at 1 year 13.2% vs 18.3%; 1.9 vs 2.7 stents per patient
FAME 2 (2012)888 randomized patients, stable disease with FFR ≤0.80PCI plus medical therapy vs medical therapyDeath, MI, or urgent revascularization 4.3% vs 12.7% (stopped early); 13.9% vs 27.0% at 5 years
DEFINE-FLAIR (2017)2,492 patientsiFR (≤0.89) vs FFR guidanceDeath, MI, or unplanned revascularization at 1 year 6.8% vs 7.0%, noninferior
iFR-SWEDEHEART (2017)2,037 patients, stable angina or ACSiFR vs FFR guidance6.7% vs 6.1% at 1 year, noninferior; 21.5% vs 19.9% at 5 years
FAME 3 (2022)1,500 patients, three-vessel disease without left mainFFR-guided PCI vs CABGDeath, MI, stroke, or repeat revascularization at 1 year 10.6% vs 6.9%, noninferiority not shown
FLOWER-MI (2021)1,163 patients, STEMI with multivessel diseaseFFR- vs angiography-guided complete revascularizationDeath, MI, or urgent revascularization at 1 year 5.5% vs 4.2%, no significant difference
FRAME-AMI (2023)562 patients, acute MI with multivessel diseaseFFR- vs angiography-guided nonculprit PCIDeath, MI, or repeat revascularization 7.4% vs 19.7% at a median 3.5 years
FAVOR III China (2021)3,825 patientsQFR-guided vs angiography-guided PCIDeath, MI, or ischemia-driven revascularization at 1 year 5.8% vs 8.8%
FAVOR III Europe (2024)2,000 patients, intermediate stenosisQFR- vs FFR-guided strategy6.7% vs 4.2% at 12 months; noninferiority not met
NOTION-3 (2024)455 patients undergoing TAVI with FFR ≤0.80 or stenosis ≥90%PCI vs conservative treatmentDeath, MI, or urgent revascularization 26% vs 36% at a median 2 years

Randomized trials of physiology-guided revascularization. ACS, acute coronary syndrome; CABG, coronary artery bypass grafting; MI, myocardial infarction; QFR, quantitative flow ratio; TAVI, transcatheter aortic valve implantation.

FAME 3: FFR-guided PCI versus bypass surgery

FAME 3 randomized 1,500 patients with three-vessel coronary disease without left main involvement at 48 centers to FFR-guided PCI with current-generation zotarolimus-eluting stents or to coronary bypass surgery. Patients assigned to PCI received a mean of 3.7 stents, and those assigned to surgery 3.4 distal anastomoses. At 1 year, death, myocardial infarction, stroke, or repeat revascularization occurred in 10.6% after FFR-guided PCI and 6.9% after surgery (hazard ratio 1.5; 95% CI 1.1 to 2.2), so FFR-guided PCI was not shown to be noninferior. Major bleeding, arrhythmia, and acute kidney injury were more frequent with surgery.

The prespecified 5-year analysis used death, stroke, or myocardial infarction as its end point. The composite occurred in 16% after PCI and 14% after surgery (hazard ratio 1.16; 95% CI 0.89 to 1.52). Death (7% in both groups) and stroke (2% vs 3%) did not differ, whereas myocardial infarction (8% vs 5%; hazard ratio 1.57) and repeat revascularization (16% vs 8%; hazard ratio 2.02) were more frequent after PCI. FFR guidance narrowed the gap between PCI and surgery seen in earlier multivessel trials without closing it for myocardial infarction and repeat revascularization. The results inform shared decision-making by the Heart Team (PCI or CABG in multivessel disease).

Physiology in acute coronary syndromes and nonculprit lesions

FFR is not used to judge the culprit lesion of an acute myocardial infarction. Microvascular obstruction, edema, and distal embolization in the infarct territory limit hyperemic flow, so the pressure drop across the culprit is smaller than its anatomic severity would produce, and FFR can be falsely reassuring. The culprit is identified and treated on clinical, ECG, and angiographic grounds, with intravascular imaging when the mechanism is uncertain (angiography and physiology in NSTE-ACS).

Nonculprit arteries in remote territories have a more normal microcirculation, and physiology can select nonculprit lesions for complete revascularization. Three trials define the evidence:

The timing of nonculprit revascularization and the role of angiography-guided complete revascularization are covered on the STEMI hub.

Physiology in severe aortic stenosis

Severe aortic stenosis changes coronary physiology: left ventricular hypertrophy and high diastolic pressures reduce hyperemic flow and coronary flow reserve, and resting flow is increased. FFR measured before valve replacement can therefore change after it, and NHPRs and FFR diverge more often in this population.

NOTION-3 randomized 455 patients (median age 82 years) with severe symptomatic aortic stenosis undergoing TAVI. Patients had at least one stenosis with FFR 0.80 or less or a diameter stenosis of 90% or more and were randomized to PCI or conservative treatment. At a median 2 years, death, myocardial infarction, or urgent revascularization occurred in 26% with PCI and 36% with conservative treatment (hazard ratio 0.71; 95% CI 0.51 to 0.99), and bleeding was more frequent with PCI (28% vs 20%). Coronary assessment before valve intervention is detailed on the aortic stenosis hub.

Post-PCI physiology

FFR measured after stenting reflects residual focal disease, stent underexpansion, edge problems, and diffuse disease. In an individual patient meta-analysis of 5,277 patients (5,869 vessels) with FFR measured after drug-eluting stent implantation, the median post-PCI FFR was 0.89, and 11.8% of vessels had a value of 0.80 or less. Target vessel failure at 2 years rose by 4% for a 0.01 decrease in FFR (adjusted hazard ratio 1.04 per 0.01). In TARGET-FFR (260 patients), 68.1% had an FFR below 0.90 after angiographically guided PCI. A physiology-guided optimization strategy led to further intervention in 30.5%, did not significantly increase the proportion with a final FFR of 0.90 or more, and reduced the proportion with a final FFR of 0.80 or less by 11.2 percentage points. A low post-PCI value prompts a pullback to separate a correctable focal gradient from diffuse disease, and intravascular imaging to assess stent expansion.

Angiography-derived FFR

Angiography-derived FFR estimates the pressure ratio from the angiogram without a pressure wire or hyperemic drug. Software reconstructs the vessel in three dimensions from two angiographic projections, estimates flow from contrast transit (frame count) or a fixed assumed hyperemic velocity, and computes the pressure drop along the vessel. Platforms include the quantitative flow ratio (QFR), vessel FFR (vFFR), and FFRangio. Thresholds and accuracy are specific to the platform that was validated. Results depend on image quality: projections without overlap or foreshortening, adequate contrast filling, frame-rate settings, and a reliable flow estimate. Ostial left main lesions, severe tortuosity, and acute infarct territories are poorly suited.

FAVOR III China randomized 3,825 patients with at least one lesion of 50% to 90% diameter stenosis in a vessel of 2.5 mm or more to QFR-guided PCI (PCI only if QFR 0.80 or less) or angiography-guided PCI, in a sham-controlled design. Death, myocardial infarction, or ischemia-driven revascularization at 1 year occurred in 5.8% vs 8.8% (hazard ratio 0.65), driven by fewer myocardial infarctions and revascularizations. At 5 years, the composite was 17.5% vs 21.1% (hazard ratio 0.80), and the benefit accrued mostly in the first 2 years.

FAVOR III Europe compared a QFR-based with an FFR-based strategy in 2,000 patients with intermediate stenoses of 40% to 90%. The 12-month composite of death, myocardial infarction, and unplanned revascularization was 6.7% with QFR and 4.2% with FFR (hazard ratio 1.63), and QFR did not meet noninferiority. The two trials place angiography-derived FFR above visual angiography and below wire-based FFR.

The 2024 European Society of Cardiology (ESC) chronic coronary syndromes guideline recommends evaluating the functional severity of intermediate stenoses by invasive functional testing (FFR or iFR) before revascularization when angiography is performed. CT-derived FFR is a separate noninvasive method (CT-FFR).

Coronary flow reserve and microvascular resistance

FFR and NHPRs assess the epicardial artery. Coronary flow reserve (CFR), the ratio of hyperemic to resting flow measured by thermodilution or Doppler, reflects both the epicardial artery and the microcirculation; a thermodilution value below 2.0 is abnormal, and Doppler studies have used a cutoff of 2.5 or lower (Kunadian 2020). The index of microcirculatory resistance (IMR), hyperemic distal pressure multiplied by the hyperemic mean transit time, assesses the microcirculation; a value of 25 or more indicates microvascular dysfunction.

A normal FFR with a low CFR indicates diffuse epicardial disease or microvascular dysfunction, and a lesion with normal FFR is not stented to treat angina. In severe microvascular dysfunction, hyperemic flow is low through the stenosis and the reference circulation alike, and FFR can understate an epicardial stenosis. Protocols, the resistive reserve ratio, absolute flow, and endotypes are on the coronary function testing hub.

Coronary physiology interpreter

The interpreter applies the validated thresholds to measured FFR, NHPR, CFR, and IMR, and adds the trial evidence relevant to the clinical setting and the pullback pattern.

FFR, nonhyperemic ratio, CFR, and IMR

Adult pressure-wire physiology
FFR—
Nonhyperemic ratio—
Microvascular indices—
—

Thresholds: FFR ≤0.80 (FAME, FAME 2), gray zone 0.75–0.80; iFR, RFR, and dPR ≤0.89 (DEFINE-FLAIR, iFR-SWEDEHEART, VALIDATE RFR, VERIFY2); CFR <2.0 by thermodilution and IMR ≥25 (European Association of Percutaneous Cardiovascular Interventions [EAPCI] consensus, Kunadian 2020; 2023 AHA/ACC chronic coronary disease guideline). Discordance after Cook 2017. Either pressure index alone is sufficient; CFR and IMR refine the interpretation.

Guideline recommendations for invasive physiology and imaging

RecommendationGuidelineClass
FFR or a proven nonhyperemic ratio before PCI in patients with angina or an anginal equivalent, no prior ischemia evaluation, and angiographically intermediate stenoses2021 ACC/AHA/SCAI revascularization; 2023 AHA/ACC chronic coronary disease1 (Level A)
IVUS for procedural guidance, particularly in left main or complex stenting2021 ACC/AHA/SCAI2a
OCT as an alternative to IVUS for procedural guidance, except in ostial left main disease2021 ACC/AHA/SCAI2a
IVUS or OCT to determine the mechanism of stent failure2021 ACC/AHA/SCAI2a
Radial access in preference to femoral access for PCI, to reduce bleeding and vascular complications2021 ACC/AHA/SCAI1
Unfractionated heparin as the anticoagulant for PCI unless contraindicated2021 ACC/AHA/SCAI1
Embolic protection for saphenous vein graft PCI2021 ACC/AHA/SCAI2a
Invasive functional testing (FFR or iFR) of intermediate stenoses before revascularization when angiography is performed2024 ESC chronic coronary syndromesRecommended

Recommendations on invasive physiology, intravascular imaging, and access. The microvascular testing recommendations of the 2023 guideline are on the hub on ischemia with nonobstructive coronary arteries (INOCA).

Post-procedure care and same-day discharge

After diagnostic angiography, the access site, distal pulses, rhythm, blood pressure, symptoms, and urine output are monitored, and kidney function is rechecked in patients at risk of contrast-associated injury. Radial hemostasis uses a compression band with patent hemostasis, in which radial flow is preserved during compression to prevent occlusion; femoral hemostasis uses manual compression or a closure device, followed by bed rest. Most patients go home the same day after an uncomplicated diagnostic study, and selected patients after uncomplicated elective PCI. Discharge instructions cover access-site bleeding and swelling, hand or leg symptoms, chest pain, and the antiplatelet regimen.

Errors in reading the angiogram and the pressure tracing

References

  1. Lawton JS, Tamis-Holland JE, Bangalore S, et al. 2021 ACC/AHA/SCAI guideline for coronary artery revascularization: a report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation. 2022;145:e18–e114. doi:10.1161/CIR.0000000000001038
  2. Virani SS, Newby LK, Arnold SV, et al. 2023 AHA/ACC/ACCP/ASPC/NLA/PCNA guideline for the management of patients with chronic coronary disease: a report of the American Heart Association/American College of Cardiology Joint Committee on Clinical Practice Guidelines. Circulation. 2023;148:e9–e119. doi:10.1161/CIR.0000000000001168
  3. Vrints C, Andreotti F, Koskinas KC, et al. 2024 ESC guidelines for the management of chronic coronary syndromes. Eur Heart J. 2024;45:3415–3537. doi:10.1093/eurheartj/ehae177
  4. Naidu SS, Abbott JD, Bagai J, et al. SCAI expert consensus update on best practices in the cardiac catheterization laboratory. Catheter Cardiovasc Interv. 2021;98:255–276. doi:10.1002/ccd.29744
  5. Blankenship JC, Gigliotti OS, Feldman DN, et al. Ad hoc percutaneous coronary intervention: a consensus statement from the Society for Cardiovascular Angiography and Interventions. Catheter Cardiovasc Interv. 2013;81:748–758. doi:10.1002/ccd.24701
  6. Patel MR, Bailey SR, Bonow RO, et al. ACCF/SCAI/AATS/AHA/ASE/ASNC/HFSA/HRS/SCCM/SCCT/SCMR/STS 2012 appropriate use criteria for diagnostic catheterization. J Am Coll Cardiol. 2012;59:1995–2027. doi:10.1016/j.jacc.2012.03.003
  7. Winchester DE, Maron DJ, Blankstein R, et al. ACC/AHA/ASE/ASNC/ASPC/HFSA/HRS/SCAI/SCCT/SCMR/STS 2023 multimodality appropriate use criteria for the detection and risk assessment of chronic coronary disease. J Am Coll Cardiol. 2023;81:2445–2467. doi:10.1016/j.jacc.2023.03.410
  8. DISCHARGE Trial Group; Maurovich-Horvat P, Bosserdt M, et al. CT or invasive coronary angiography in stable chest pain. N Engl J Med. 2022;386:1591–1602. doi:10.1056/NEJMoa2200963
  9. Klaudel J, Glaza M, Klaudel B, et al. Catheter-induced coronary artery and aortic dissections: a study of mechanisms, risk factors and propagation causes. Cardiol J. 2024;31:398–408. doi:10.5603/CJ.a2022.0050
  10. Fukumoto Y, Tsutsui H, Tsuchihashi M, et al. The incidence and risk factors of cholesterol embolization syndrome, a complication of cardiac catheterization: a prospective study. J Am Coll Cardiol. 2003;42:211–216. doi:10.1016/s0735-1097(03)00579-5
  11. Knaapen M, Koch AH, Koch C, et al. Prevalence of left and balanced coronary arterial dominance decreases with increasing age of patients at autopsy: a postmortem coronary angiograms study. Cardiovasc Pathol. 2013;22:49–53. doi:10.1016/j.carpath.2012.02.012
  12. Aricatt DP, Prabhu A, Avadhani R, et al. A study of coronary dominance and its clinical significance. Folia Morphol (Warsz). 2023;82:102–107. doi:10.5603/FM.a2022.0005
  13. Qian JY, Zhang F, Dong M, et al. Prevalence and characteristics of myocardial bridging in coronary angiogram: data from consecutive 5525 patients. Chin Med J (Engl). 2009;122:632–635.
  14. Swaye PS, Fisher LD, Litwin P, et al. Aneurysmal coronary artery disease. Circulation. 1983;67:134–138. doi:10.1161/01.cir.67.1.134
  15. Tonino PA, Fearon WF, De Bruyne B, et al. Angiographic versus functional severity of coronary artery stenoses in the FAME study. J Am Coll Cardiol. 2010;55:2816–2821. doi:10.1016/j.jacc.2009.11.096
  16. Ellis SG, Vandormael MG, Cowley MJ, et al. Coronary morphologic and clinical determinants of procedural outcome with angioplasty for multivessel coronary disease: implications for patient selection. Circulation. 1990;82:1193–1202. doi:10.1161/01.cir.82.4.1193
  17. Louvard Y, Medina A. Definitions and classifications of bifurcation lesions and treatment. EuroIntervention. 2015;11 Suppl V:V23–V26. doi:10.4244/EIJV11SVA5
  18. Sianos G, Morel MA, Kappetein AP, et al. The SYNTAX score: an angiographic tool grading the complexity of coronary artery disease. EuroIntervention. 2005;1:219–227.
  19. TIMI Study Group. The Thrombolysis in Myocardial Infarction (TIMI) trial: phase I findings. N Engl J Med. 1985;312:932–936. doi:10.1056/NEJM198504043121437
  20. Anderson JL, Karagounis LA, Becker LC, et al. TIMI perfusion grade 3 but not grade 2 results in improved outcome after thrombolysis for myocardial infarction: ventriculographic, enzymatic, and electrocardiographic evidence from the TEAM-3 study. Circulation. 1993;87:1829–1839. doi:10.1161/01.cir.87.6.1829
  21. Gibson CM, Cannon CP, Daley WL, et al. TIMI frame count: a quantitative method of assessing coronary artery flow. Circulation. 1996;93:879–888. doi:10.1161/01.cir.93.5.879
  22. van 't Hof AW, Liem A, Suryapranata H, et al. Angiographic assessment of myocardial reperfusion in patients treated with primary angioplasty for acute myocardial infarction: myocardial blush grade. Circulation. 1998;97:2302–2306. doi:10.1161/01.cir.97.23.2302
  23. Gibson CM, Cannon CP, Murphy SA, et al. Relationship of TIMI myocardial perfusion grade to mortality after administration of thrombolytic drugs. Circulation. 2000;101:125–130. doi:10.1161/01.cir.101.2.125
  24. Gibson CM, de Lemos JA, Murphy SA, et al. Combination therapy with abciximab reduces angiographically evident thrombus in acute myocardial infarction: a TIMI 14 substudy. Circulation. 2001;103:2550–2554. doi:10.1161/01.cir.103.21.2550
  25. Rentrop KP, Cohen M, Blanke H, Phillips RA. Changes in collateral channel filling immediately after controlled coronary artery occlusion by an angioplasty balloon in human subjects. J Am Coll Cardiol. 1985;5:587–592. doi:10.1016/s0735-1097(85)80380-6
  26. Werner GS, Ferrari M, Heinke S, et al. Angiographic assessment of collateral connections in comparison with invasively determined collateral function in chronic coronary occlusions. Circulation. 2003;107:1972–1977. doi:10.1161/01.CIR.0000061953.72662.3A
  27. Huber MS, Mooney JF, Madison J, Mooney MR. Use of a morphologic classification to predict clinical outcome after dissection from coronary angioplasty. Am J Cardiol. 1991;68:467–471. doi:10.1016/0002-9149(91)90780-o
  28. Ellis SG, Ajluni S, Arnold AZ, et al. Increased coronary perforation in the new device era: incidence, classification, management, and outcome. Circulation. 1994;90:2725–2730. doi:10.1161/01.cir.90.6.2725
  29. de la Torre Hernandez JM, Hernández Hernandez F, Alfonso F, et al. Prospective application of pre-defined intravascular ultrasound criteria for assessment of intermediate left main coronary artery lesions: results from the multicenter LITRO study. J Am Coll Cardiol. 2011;58:351–358. doi:10.1016/j.jacc.2011.02.064
  30. Bech GJ, De Bruyne B, Pijls NH, et al. Fractional flow reserve to determine the appropriateness of angioplasty in moderate coronary stenosis: a randomized trial (DEFER). Circulation. 2001;103:2928–2934. doi:10.1161/01.cir.103.24.2928
  31. Zimmermann FM, Ferrara A, Johnson NP, et al. Deferral vs. performance of percutaneous coronary intervention of functionally non-significant coronary stenosis: 15-year follow-up of the DEFER trial. Eur Heart J. 2015;36:3182–3188. doi:10.1093/eurheartj/ehv452
  32. Tonino PA, De Bruyne B, Pijls NH, et al. Fractional flow reserve versus angiography for guiding percutaneous coronary intervention (FAME). N Engl J Med. 2009;360:213–224. doi:10.1056/NEJMoa0807611
  33. De Bruyne B, Pijls NH, Kalesan B, et al. Fractional flow reserve-guided PCI versus medical therapy in stable coronary disease (FAME 2). N Engl J Med. 2012;367:991–1001. doi:10.1056/NEJMoa1205361
  34. Xaplanteris P, Fournier S, Pijls NHJ, et al. Five-year outcomes with PCI guided by fractional flow reserve. N Engl J Med. 2018;379:250–259. doi:10.1056/NEJMoa1803538
  35. Fearon WF, Zimmermann FM, De Bruyne B, et al. Fractional flow reserve-guided PCI as compared with coronary bypass surgery (FAME 3). N Engl J Med. 2022;386:128–137. doi:10.1056/NEJMoa2112299
  36. Fearon WF, Zimmermann FM, Ding VY, et al. Outcomes after fractional flow reserve-guided percutaneous coronary intervention versus coronary artery bypass grafting (FAME 3): 5-year follow-up of a multicentre, open-label, randomised trial. Lancet. 2025;405:1481–1490. doi:10.1016/S0140-6736(25)00505-7
  37. Sen S, Escaned J, Malik IS, et al. Development and validation of a new adenosine-independent index of stenosis severity from coronary wave-intensity analysis: results of the ADVISE study. J Am Coll Cardiol. 2012;59:1392–1402. doi:10.1016/j.jacc.2011.11.003
  38. Svanerud J, Ahn JM, Jeremias A, et al. Validation of a novel non-hyperaemic index of coronary artery stenosis severity: the Resting Full-cycle Ratio (VALIDATE RFR) study. EuroIntervention. 2018;14:806–814. doi:10.4244/EIJ-D-18-00342
  39. Van't Veer M, Pijls NHJ, Hennigan B, et al. Comparison of different diastolic resting indexes to iFR: are they all equal? J Am Coll Cardiol. 2017;70:3088–3096. doi:10.1016/j.jacc.2017.10.066
  40. Davies JE, Sen S, Dehbi HM, et al. Use of the instantaneous wave-free ratio or fractional flow reserve in PCI (DEFINE-FLAIR). N Engl J Med. 2017;376:1824–1834. doi:10.1056/NEJMoa1700445
  41. Götberg M, Christiansen EH, Gudmundsdottir IJ, et al. Instantaneous wave-free ratio versus fractional flow reserve to guide PCI (iFR-SWEDEHEART). N Engl J Med. 2017;376:1813–1823. doi:10.1056/NEJMoa1616540
  42. Götberg M, Berntorp K, Rylance R, et al. 5-year outcomes of PCI guided by measurement of instantaneous wave-free ratio versus fractional flow reserve. J Am Coll Cardiol. 2022;79:965–974. doi:10.1016/j.jacc.2021.12.030
  43. Escaned J, Travieso A, Dehbi HM, et al. Coronary revascularization guided with fractional flow reserve or instantaneous wave-free ratio: a 5-year follow-up of the DEFINE FLAIR randomized clinical trial. JAMA Cardiol. 2025;10:25–31. doi:10.1001/jamacardio.2024.3314
  44. Eftekhari A, Holck EN, Westra J, et al. Instantaneous wave free ratio vs. fractional flow reserve and 5-year mortality: iFR SWEDEHEART and DEFINE FLAIR. Eur Heart J. 2023;44:4376–4384. doi:10.1093/eurheartj/ehad582
  45. Cook CM, Jeremias A, Petraco R, et al. Fractional flow reserve/instantaneous wave-free ratio discordance in angiographically intermediate coronary stenoses: an analysis using Doppler-derived coronary flow measurements. JACC Cardiovasc Interv. 2017;10:2514–2524. doi:10.1016/j.jcin.2017.09.021
  46. Rigattieri S, Biondi Zoccai G, Sciahbasi A, et al. Meta-analysis of head-to-head comparison of intracoronary versus intravenous adenosine for the assessment of fractional flow reserve. Am J Cardiol. 2017;120:563–568. doi:10.1016/j.amjcard.2017.05.024
  47. van Nunen LX, Lenders GD, Schampaert S, et al. Single bolus intravenous regadenoson injection versus central venous infusion of adenosine for maximum coronary hyperaemia in fractional flow reserve measurement. EuroIntervention. 2015;11:905–913. doi:10.4244/EIJY14M08_10
  48. Nakayama M, Tanaka N, Sakoda K, et al. Papaverine-induced polymorphic ventricular tachycardia during coronary flow reserve study of patients with moderate coronary artery disease. Circ J. 2015;79:530–536. doi:10.1253/circj.CJ-14-1118
  49. Carvalho PEP, Collet C, De Bruyne B, et al. The pullback pressure gradient: a physiologic index to differentiate focal from diffuse coronary artery disease. JACC Adv. 2025;4:101679. doi:10.1016/j.jacadv.2025.101679
  50. Hwang D, Koo BK, Zhang J, et al. Prognostic implications of fractional flow reserve after coronary stenting: a systematic review and meta-analysis. JAMA Netw Open. 2022;5:e2232842. doi:10.1001/jamanetworkopen.2022.32842
  51. Collison D, Didagelos M, Aetesam-Ur-Rahman M, et al. Post-stenting fractional flow reserve vs coronary angiography for optimization of percutaneous coronary intervention (TARGET-FFR). Eur Heart J. 2021;42:4656–4668. doi:10.1093/eurheartj/ehab449
  52. Puymirat E, Cayla G, Simon T, et al. Multivessel PCI guided by FFR or angiography for myocardial infarction (FLOWER-MI). N Engl J Med. 2021;385:297–308. doi:10.1056/NEJMoa2104650
  53. Lee JM, Kim HK, Park KH, et al. Fractional flow reserve versus angiography-guided strategy in acute myocardial infarction with multivessel disease: a randomized trial (FRAME-AMI). Eur Heart J. 2023;44:473–484. doi:10.1093/eurheartj/ehac763
  54. Biscaglia S, Guiducci V, Escaned J, et al. Complete or culprit-only PCI in older patients with myocardial infarction (FIRE). N Engl J Med. 2023;389:889–898. doi:10.1056/NEJMoa2300468
  55. Lønborg J, Jabbari R, Sabbah M, et al. PCI in patients undergoing transcatheter aortic-valve implantation (NOTION-3). N Engl J Med. 2024;391:2189–2200. doi:10.1056/NEJMoa2401513
  56. Xu B, Tu S, Song L, et al. Angiographic quantitative flow ratio-guided coronary intervention (FAVOR III China): a multicentre, randomised, sham-controlled trial. Lancet. 2021;398:2149–2159. doi:10.1016/S0140-6736(21)02248-0
  57. Zhang H, Guan C, Jin Z, et al. Angiographic quantitative flow ratio-guided coronary intervention: 5-year follow-up from the FAVOR III China randomized trial. J Am Coll Cardiol. 2026;88:800–812. doi:10.1016/j.jacc.2026.04.037
  58. Andersen BK, Sejr-Hansen M, Maillard L, et al. Quantitative flow ratio versus fractional flow reserve for coronary revascularisation guidance (FAVOR III Europe): a multicentre, randomised, non-inferiority trial. Lancet. 2024;404:1835–1846. doi:10.1016/S0140-6736(24)02175-5
  59. Anderson JL, Karagounis LA, Califf RM. Metaanalysis of five reported studies on the relation of early coronary patency grades with mortality and outcomes after acute myocardial infarction. Am J Cardiol. 1996;78:1–8. doi:10.1016/s0002-9149(96)00217-2
  60. Kunadian V, Chieffo A, Camici PG, et al. An EAPCI expert consensus document on ischaemia with non-obstructive coronary arteries in collaboration with European Society of Cardiology Working Group on Coronary Pathophysiology & Microcirculation endorsed by Coronary Vasomotor Disorders International Study Group. Eur Heart J. 2020;41:3504–3520. doi:10.1093/eurheartj/ehaa503
  61. Sianos G, Papafaklis MI, Daemen J, et al. Angiographic stent thrombosis after routine use of drug-eluting stents in ST-segment elevation myocardial infarction: the importance of thrombus burden. J Am Coll Cardiol. 2007;50:573–583. doi:10.1016/j.jacc.2007.04.059
  62. Sianos G, Papafaklis MI, Serruys PW. Angiographic thrombus burden classification in patients with ST-segment elevation myocardial infarction treated with percutaneous coronary intervention. J Invasive Cardiol. 2010;22(10 Suppl B):6B–14B. PMID: 20947930
  63. Kelm M, Perings SM, Jax T, et al. Incidence and clinical outcome of iatrogenic femoral arteriovenous fistulas: implications for risk stratification and treatment. J Am Coll Cardiol. 2002;40:291–7. doi:10.1016/s0735-1097(02)01966-6
  64. Kontopodis N, Tsetis D, Tavlas E, et al. Ultrasound Guided Compression Versus Ultrasound Guided Thrombin Injection for the Treatment of Post-Catheterization Femoral Pseudoaneurysms: Systematic Review and Meta-Analysis of Comparative Studies. Eur J Vasc Endovasc Surg. 2016;51:815–23. doi:10.1016/j.ejvs.2016.02.012