Library › Imaging › CT-FFR, CT perfusion and myocardial CT
CT-derived fractional flow reserve, CT perfusion and myocardial CT
Physiologic and myocardial applications of cardiac CT in adults: CT-derived fractional flow reserve, static and dynamic stress CT perfusion, the transluminal attenuation gradient, late iodine enhancement, and extracellular volume.
CT-derived fractional flow reserve (CT-FFR) is read 2 cm distal to a stenosis and graded as above 0.80 (I−), 0.76 to 0.80 (I±), or 0.75 or less (I+). The 2026 consensus of the Society of Cardiovascular Computed Tomography and the Society for Cardiovascular Angiography and Interventions (SCCT/SCAI) applies it to stenoses of 50% to 90%. The 2021 chest pain guideline extends the range to 40% to 90% in proximal and middle segments. It is computed only from diagnostic-quality images acquired after nitroglycerin. Stress CT perfusion images the myocardium during vasodilator stress and remains interpretable when calcium or stents make the lumen uncertain. Delayed imaging after the same contrast dose shows myocardial scar (late iodine enhancement) and quantifies extracellular volume.
Why physiology is added to coronary CT angiography
Coronary CT angiography (CCTA) is the most sensitive noninvasive test for obstructive coronary disease, and a normal study excludes it with a high negative predictive value. Its weakness is the step from anatomy to ischemia. Percent diameter stenosis is a poor predictor of whether a lesion limits hyperemic flow. Lesion length, entrance and exit angles, plaque composition, the size of the subtended myocardium, serial disease, and the state of the microcirculation all modify the pressure loss across a given narrowing. CCTA also tends to overestimate stenosis, most of all in calcified segments, where blooming narrows the displayed lumen.
The consequence is low specificity for ischemia. In DISCOVER-FLOW, a CCTA stenosis of 50% or more had a per-vessel specificity of 39.6% against invasive fractional flow reserve (Koo 2011). In NXT, per-patient specificity of CCTA was 34%, compared with 79% for CT-FFR and 83% for invasive angiography read visually (Nørgaard 2014). In PACIFIC, CCTA was 90% sensitive and 60% specific for a fractional flow reserve of 0.80 or less (Danad 2017). Before physiologic methods were added, a substantial share of patients referred to invasive angiography after an abnormal CCTA had no lesion that warranted revascularization. In the usual-care arm of PLATFORM with planned invasive testing, 73% had no obstructive disease at catheterization (Douglas 2015).
Three CT approaches add physiology to the anatomic dataset. CT-derived fractional flow reserve models pressure and flow from the coronary tree on a resting CCTA and requires no additional acquisition or drug. Stress CT perfusion images the arrival of iodinated contrast in the myocardium during pharmacologic vasodilation and requires a stress agent and a second acquisition. The transluminal attenuation gradient infers flow from the fall in luminal contrast density along a vessel and is now used mainly in research. Delayed acquisitions add tissue characterization: late iodine enhancement for scar and extracellular volume for diffuse fibrosis and infiltration.
Basic CCTA acquisition, Coronary Artery Disease–Reporting and Data System (CAD-RADS) 2.0 stenosis categories, plaque assessment, and the randomized trials of CCTA as a first test are covered on the coronary CT angiography and calcium scoring page. The physics of CT acquisition, electrocardiographic gating, reconstruction, and the general mechanisms of CT artifacts are covered on the cardiac CT physics and protocols page.
Invasive fractional flow reserve, the reference standard
Invasive fractional flow reserve (FFR) is the ratio of maximal flow in a stenotic artery to the maximal flow the same artery would carry without the stenosis. Under maximal hyperemia, when microvascular resistance is minimal and assumed constant, flow is proportional to pressure, and FFR is measured as the ratio of mean distal coronary pressure (Pd) to mean aortic pressure (Pa). A value of 1.0 indicates no pressure loss. The ratio is specific to the epicardial lesion, independent of heart rate and blood pressure within physiologic limits, and has a sharp threshold for ischemia.
The clinical threshold of 0.80 or less comes from outcome trials. In FAME, 1,005 patients with multivessel disease were assigned to percutaneous coronary intervention (PCI) guided by angiography alone or by FFR, with stenting only of lesions with FFR 0.80 or less. The 1-year rate of death, nonfatal myocardial infarction, or repeat revascularization was 18.3% with angiographic guidance and 13.2% with FFR guidance, with fewer stents in the FFR arm (Tonino 2009). Earlier deferral studies used 0.75; values between 0.75 and 0.80 became known as the gray zone, in which ischemia is possible and decisions weigh symptoms, the territory, and the lesion together. That uncertainty near the cut point is the reason CT-FFR reporting retains a borderline band.
Invasive FFR has its own limitations, which carry into any test validated against it. It requires adequate hyperemia; incomplete vasodilation raises the measured value and underestimates significance. In severe microvascular dysfunction, maximal flow is low through both the stenotic and the reference circulation, so FFR can be normal despite ischemia. In serial lesions, the value distal to both lesions reflects their combined effect, and the contribution of the individual lesions is estimated from a pullback recording. CT-FFR was developed and validated against invasive FFR. Its accuracy statistics describe agreement with invasive FFR only; agreement with ischemia measured by perfusion is a separate question.
How CT-FFR is computed
CT-FFR applies the physics of blood flow to a patient-specific model of the coronary arteries. The method has four steps (Taylor 2013).
- Segmentation. The aortic root and the coronary tree are segmented from the CCTA, and the luminal boundaries of all visible vessels are traced. Analysts or software correct the centerline and lumen contour where calcium, motion, or partial volume distort them.
- Boundary conditions at rest. Total resting coronary flow is estimated from myocardial mass measured on the same CCTA, on the principle that resting flow is proportional to the oxygen demand of the myocardium. Flow is distributed among branches in proportion to their size, following the allometric relation between vessel diameter and flow (Murray's law), and microvascular resistance at an outlet is set inversely proportional to its size. Aortic pressure is taken from the brachial blood pressure.
- Simulated hyperemia. The effect of adenosine is modeled as a fixed reduction of microvascular resistance, which assumes a normal microvascular response to vasodilation.
- Solution. The governing equations of fluid motion (the Navier–Stokes equations for an incompressible fluid) are solved in three dimensions, and the ratio of computed pressure at any point to computed aortic pressure is displayed as a color-coded map of the coronary tree.
Three-dimensional computational fluid dynamics requires substantial computing power and has been delivered as an off-site service: the CCTA is transmitted, analysts in a core facility build and verify the model, and a report returns hours later. Two faster approaches run on the scanner workstation. Reduced-order models solve simplified one-dimensional or lumped-parameter equations along the vessel centerlines. Machine-learning models are trained on large sets of synthetic coronary geometries with computational fluid dynamics solutions, or on invasive FFR data, and predict the pressure ratio from lumen geometry. In a meta-analysis of 54 studies, the pooled sensitivity and specificity of on-site and off-site CT-FFR were similar (sensitivity 0.84 vs. 0.85; specificity 0.80 vs. 0.73) (Celeng 2019). On-site, machine-learning CT-FFR was tested as a management strategy in the TARGET randomized trial (Yang 2023). Products differ in their segmentation, boundary assumptions, and training data, so a published threshold or accuracy figure applies to the platform and version in which it was obtained.
| Approach | Computation | Where it runs | Practical implications |
|---|---|---|---|
| Three-dimensional computational fluid dynamics | Full Navier–Stokes solution in a patient-specific three-dimensional model | Usually off-site in a core facility | Most outcome data (PLATFORM, ADVANCE, FORECAST, PRECISE); data transfer and turnaround time; studies of inadequate quality rejected before analysis |
| Reduced-order modeling | One-dimensional or lumped-parameter equations along centerlines | On-site workstation | Minutes per study; segmentation controlled by the local reader, so local training and quality control determine accuracy |
| Machine learning | Model trained on synthetic geometries or invasive FFR data predicts pressure ratio from geometry | On-site workstation or cloud | Fast; performance depends on the training population and may fall outside it (unusual anatomy, heavy calcium, stents) |
Approaches to CT-derived fractional flow reserve. All use resting CCTA geometry and simulate hyperemia; none measures pressure or flow.
Because the model derives physiology from geometry and from assumed boundary conditions, two classes of error follow. Geometric error arises when the lumen on which the model is built is wrong: motion, misregistration, blooming from calcium or metal, poor opacification, and thick reconstructions all change the modeled lumen and therefore the computed pressure loss. Physiologic error arises when the patient departs from the assumptions: microvascular dysfunction, an abnormal relation between myocardial mass and flow (left ventricular hypertrophy, prior infarction, collateral-dependent myocardium), and the absence of measured aortic pressure. Neither can be corrected by repeating the computation.
Acquisition and image-quality requirements for CT-FFR
CT-FFR is a post-processing step applied to a CCTA, so the acquisition is a standard coronary acquisition optimized for lumen definition. The 2026 SCCT/SCAI consensus states that CT-FFR is performed only on high-quality CCTA, with heart-rate control when needed and sublingual nitroglycerin before the acquisition (Weir-McCall 2026). Nitroglycerin dilates the epicardial arteries; without it, the lumen is smaller, the computed resistance higher, and the CT-FFR value falsely low. Thin-slice reconstructions in the best diastolic or systolic phase, with a kernel that limits blooming, give the model the most accurate lumen.
Some studies cannot be analyzed. In the PROMISE substudy, CT-FFR could be computed in 67% (181 of 271) of eligible patients whose CCTA scans had been acquired across many sites in the early years of the technique (Lu 2017). In PACIFIC, 83% (505 of 612) of vessels were evaluable. In the intention-to-diagnose analysis, which counted nonevaluable vessels as errors, the per-vessel area under the curve of CT-FFR fell from 0.94 to 0.79, significantly below the intention-to-diagnose value of 0.90 for positron emission tomography (PET). The per-patient value fell to 0.83, compared with 0.86 for PET (Driessen 2019). Later cohorts report lower rejection rates: 2.9% in the ADVANCE registry and 8.4% in routine clinical submissions. Motion artifact was the main cause of rejection, and thinner sections and lower heart rate predicted successful analysis (Pontone 2019). A study rejected for analysis returns the patient to the original diagnostic question.
| Factor | Effect on the model | Mitigation |
|---|---|---|
| Coronary motion | Blurred or doubled lumen; false narrowing at the lesion | Heart-rate control; best-phase reconstruction; scanner with adequate temporal resolution |
| Misregistration (step artifact) | Lumen offset between slabs; false pressure step at the slab boundary | Single-beat or high-pitch acquisition; recognition of a step that coincides with an ectopic beat |
| No nitroglycerin | Smaller modeled lumen; values falsely low throughout | Sublingual nitroglycerin unless contraindicated |
| Poor or uneven opacification | Lumen boundary uncertain; distal segments lost | Adequate iodine delivery rate; bolus timing; saline chaser |
| Image noise | Irregular contour; spurious narrowing in small vessels | Tube settings matched to body size; iterative or deep-learning reconstruction |
| Dense calcium | Blooming narrows the lumen; segmentation depends on editing | Sharper kernel; thin slices; high-resolution or photon-counting scanners |
| Metal (stents, clips) | Lumen inside the stent not reliably modeled | No CT-FFR decisions on stented segments; assessment of nonstented arteries |
Image-quality factors that determine whether CT-FFR is reliable. A value computed from a segment that is not diagnostic for stenosis grading is not diagnostic for physiology.
Selecting lesions for CT-FFR
CT-FFR answers one question: whether a specific stenosis is likely to be hemodynamically significant. It is ordered when that answer can change the next investigation or treatment, most often the decision whether to proceed to invasive angiography.
The 2021 American Heart Association/American College of Cardiology (AHA/ACC) multisociety chest pain guideline gives a Class 2a recommendation (Level B-NR) for CT-FFR in patients with chest pain who have a stenosis of 40% to 90% in a proximal or middle coronary segment on CCTA. The purpose is to diagnose vessel-specific ischemia and guide decisions about invasive coronary angiography (Gulati 2021). CAD-RADS 2.0 lists functional assessment, by CT-FFR, CT perfusion, or stress testing, among the management options for CAD-RADS 3 (50% to 69%) and CAD-RADS 4A (70% to 99% in one or two vessels) (Cury 2022). The 2026 SCCT/SCAI consensus recommends CT-FFR for diameter stenoses of 50% to 90% in vessels other than the left main when the result could change management. It does not recommend CT-FFR below 30% and finds the evidence for stenoses of 30% to 49% insufficient for a firm recommendation, although lesion location and extent may be considered (Weir-McCall 2026).
| Setting | Role of CT-FFR |
|---|---|
| Stenosis 50% to 90% in a proximal or middle segment of a vessel supplying meaningful myocardium | Principal indication; result guides referral to invasive angiography |
| Stenosis 40% to 49% in a proximal or middle segment, particularly with high-risk plaque or a long lesion | Within the 2021 guideline range; the 2026 consensus finds the evidence insufficient, so testing is selective and limited to cases where the result would change management |
| Multivessel moderate disease | Ranks lesions by physiology; identifies vessels likely to benefit from revascularization |
| CAD-RADS 4B (left main 50% or more, or three-vessel 70% or more) | Invasive angiography is indicated on anatomic grounds. CT-FFR is not used for left main stenosis. In three-vessel disease, the 2026 consensus considers it reasonable for planning revascularization and selecting target vessels |
| CAD-RADS 0 to 2, minimal or mild plaque | Not indicated; no decision depends on it |
| Total occlusion (CAD-RADS 5) | Not applicable; occlusion anatomy and viability guide management |
| Nondiagnostic segment at the lesion | Not reliable; CT perfusion, stress imaging, or invasive physiology answers the question |
| Stents and bypass grafts | Not validated; not used for decisions about stented segments or grafts. Nonstented native arteries in the same patient can be assessed |
| Acute coronary syndrome with a suspected culprit | Not used to assess a culprit lesion; the model assumes stable physiology |
Lesion selection for CT-FFR, based on the 2021 AHA/ACC chest pain guideline, CAD-RADS 2.0, and the 2026 SCCT/SCAI consensus.
In acute chest pain, CT-FFR has been used after a CCTA that shows intermediate stenosis once acute coronary syndrome has been excluded by electrocardiogram and serial troponin. In a single-center registry of 389 low-risk emergency department patients, revascularization was appropriate in 65% of patients with a positive CT-FFR and 2% of those with a negative result, with no deaths after a negative CT-FFR over about 3.5 years (Schott 2024). That experience supports the use of CT-FFR for stable-appearing intermediate lesions after an acute presentation, a role that excludes evaluation of a suspected culprit.
Reading CT-FFR: measurement point, bands, and the translesional gradient
Where the value is read. CT-FFR falls continuously along the length of a vessel, because even a normal artery loses pressure through viscous friction and because the lumen tapers distally. The lowest value in a vessel, usually at the distal tip, reflects that cumulative loss and is not the value of any lesion. In a cohort of 192 patients, CT-FFR was positive in 55.7% when the lowest value per vessel was used and in 31.3% when the value within 2 cm distal to a stenosis was used. Of the patients positive by the lowest value, 44% were reclassified as negative, most often those with stenoses below 70%. Revascularization after invasive angiography was more frequent when positivity was defined at the lesion (Kueh 2017). CAD-RADS 2.0 recommended reading the value 1 to 2 cm distal to the stenosis. The 2026 SCCT/SCAI consensus specifies 2 cm distal to the stenosis, beyond the zone of pressure recovery, and that value is reported as the lesion-specific CT-FFR.
Bands. CAD-RADS 2.0 reports the lesion-specific value in three bands, carried into the ischemia modifier. A value above 0.80 is normal and coded I−. A value of 0.76 to 0.80 is borderline and coded I±. A value of 0.75 or less indicates a lesion likely to be hemodynamically significant and is coded I+. Exactly 0.80 falls in the borderline band. The 2026 SCCT/SCAI consensus describes the same continuum as probabilities of flow limitation: low above 0.80, intermediate from 0.70 to 0.80, and high below 0.70 (Weir-McCall 2026). The bands differ from the binary invasive threshold of 0.80 because a modeled value carries more uncertainty than a measured one. The error of CT-FFR against invasive FFR is largest near the cut point. In DISCOVER-FLOW, CT-FFR slightly underestimated invasive FFR, by a mean of 0.022, with a standard deviation of 0.116 (Koo 2011): an estimate of 0.79 is compatible with an invasive value on either side of 0.80.
Translesional gradient. The drop in CT-FFR across a lesion (ΔCT-FFR) is the value just proximal to the stenosis minus the value 2 cm distal to it. A drop of 0.12 or more, together with a value of 0.80 or less, indicates a high probability of lesion-specific flow limitation; the consensus notes that this cut point has not yet been validated prospectively (Weir-McCall 2026). A value of 0.92 before a lesion and 0.79 after it gives a drop of 0.13: the lesion is borderline by its absolute value, and the focal loss of pressure points to the stenosis as its source. In EMERALD, a larger ΔCT-FFR was also one of the adverse hemodynamic characteristics of lesions that later caused acute coronary syndrome (Lee 2019). The drop supports interpretation and is not a stand-alone indication for revascularization.
| Lesion-specific CT-FFR (2 cm distal) | CAD-RADS modifier | Interpretation |
|---|---|---|
| Above 0.80 | I− | Hemodynamic significance unlikely; preventive and antianginal therapy |
| 0.76 to 0.80 | I± | Borderline; integrated with symptoms, lesion location, vessel size, plaque features, and the translesional drop |
| 0.75 or less | I+ | Hemodynamic significance likely; invasive angiography when symptoms and expected benefit justify revascularization |
| Drop across the lesion of 0.12 or more | Supportive | Focal pressure loss; with a value of 0.80 or less, high probability of lesion-specific flow limitation |
| Model not interpretable at the lesion | No I modifier | Physiology obtained by another method if needed |
Reporting bands for CT-FFR from CAD-RADS 2.0, with the measurement point and the translesional threshold from the 2026 SCCT/SCAI consensus.
The calculator below applies these rules to a single lesion. The verdict assumes the value was read at 2 cm distal to the stenosis on a model whose lumen at the lesion was judged accurate.
ΔCT-FFR = CT-FFR proximal to the stenosis − CT-FFR 2 cm distal to it. Bands from CAD-RADS 2.0; measurement location and the 0.12 supportive threshold from the 2026 SCCT/SCAI consensus. The modifier is assigned only when CT-FFR or CT perfusion was performed and is interpretable.
Pressure patterns along the vessel: focal, diffuse, and serial disease
A single number does not describe the physiology of a vessel. The shape of the CT-FFR curve from ostium to tip separates focal disease, which revascularization can treat, from diffuse disease, which it treats poorly.
| Pattern | Appearance along the vessel | Interpretation |
|---|---|---|
| Focal | Sharp step across a discrete stenosis; stable value beyond it | Lesion-specific significance when concordant with anatomy; favorable target for PCI |
| Diffuse | Gradual decline over a long segment without a step | Diffuse atherosclerosis; no single focal target; PCI relieves little of the pressure loss |
| Serial (tandem) | Two or more steps in one vessel | All lesions contribute; the distal value reflects both, and treating one changes the gradient across the other |
| Low value only at the tip | Normal value at the lesion; values below 0.80 only in the distal few centimeters | Tapering and mild diffuse disease; not attributed to a proximal plaque |
| Focal plus diffuse | Step at a stenosis superimposed on a steady decline | Mixed disease; expected gain from PCI is the size of the focal step |
CT-FFR pressure patterns and their meaning.
Serial lesions. Pressure losses across tandem stenoses interact. Flow through the proximal lesion is limited by the distal one, so the proximal lesion's step underestimates its isolated effect, and the reverse holds for the distal lesion. A vessel in which CT-FFR falls from 0.95 to 0.86 across a first lesion and from 0.86 to 0.74 across a second has two contributors; the whole drop is not assigned to the first. Computational models can simulate removal of one lesion and recompute the pressure field, an approach used in planning tools that predict the post-PCI value. The principle is the same as an invasive pullback: the largest step is usually treated first, and the residual physiology is reassessed.
Diffuse disease. Long segments of mild to moderate plaque produce a gradual decline that can reach values below 0.80 at the tip without any lesion that meets the band criteria at 2 cm. This pattern is common in diabetes, in older patients, and in long left anterior descending arteries. It identifies a high atherosclerotic burden that warrants intensive preventive therapy, and it predicts a smaller gain from stenting than a focal pattern with the same distal value.
Multivessel disease. Physiology can reverse the order suggested by anatomy. A 75% circumflex stenosis with a value of 0.86 at 2 cm and a 60% left anterior descending stenosis with 0.72 make the left anterior descending lesion the more likely source of ischemia. CT-FFR can therefore rank lesions and indicate the extent of hemodynamically significant disease, information used together with the anatomy when the choice between PCI and surgery is discussed with the heart team.
Discordance between anatomy and CT-FFR
Discordance between stenosis grade and CT-FFR is frequent. In the PROMISE substudy, CT-FFR was discordant with CCTA stenosis in 31% of patients and with invasive angiographic stenosis in 29%. Most patients who were later revascularized had a CT-FFR of 0.80 or less (91%), and a positive CT-FFR predicted revascularization or major adverse cardiac events more strongly than severe stenosis on CCTA (hazard ratio 4.3 vs. 2.9) (Lu 2017).
A severe stenosis with a normal CT-FFR occurs with short lesions, small vessels supplying little myocardium, distal lesions, collateral supply, and prior infarction in the territory, which reduces the flow demand. It also occurs when CCTA overestimates the stenosis. A moderate stenosis with an abnormal CT-FFR occurs with long lesions, diffuse disease in a large vessel, a large subtended territory such as the proximal left anterior descending artery, and plaque features that alter flow geometry. Evaluation of a discordant case begins with the accuracy of the model's lumen at the lesion and then addresses whether the physiology is plausible for the anatomy and territory.
Discordance between CT-FFR and invasive FFR also has known causes. CT-FFR simulates hyperemia from assumed microvascular resistance, while invasive FFR depends on the response achieved. In patients with microvascular dysfunction or left ventricular hypertrophy, the modeled hyperemic flow may exceed the true value, making CT-FFR lower than invasive FFR. Calcium blooming, small vessels, and segmentation choices bias CT-FFR downward; poor opacification and underestimated stenosis bias it upward.
Limitations of CT-FFR
Calcium. Dense calcium is a theoretical and practical concern because blooming narrows the displayed lumen. In the NXT calcium substudy of 214 patients, accuracy, sensitivity, and specificity of CT-FFR did not differ across Agatston quartiles. Discrimination remained high in patients with scores of 416 to 3,599 (area under the curve 0.86 vs. 0.92 in lower quartiles) (Nørgaard 2015). CT-FFR therefore improves on visual grading in calcified vessels when the images are of high quality and the lumen can be defined. When the lumen boundary is uncertain over the lesion despite optimal reconstruction, the value inherits that uncertainty and is reported with the limitation. CT perfusion, which images the myocardium and not the lumen, is less affected.
Stents. Metal struts cause blooming and beam hardening, and the lumen within a stent is not reliably segmented on most scanners. The 2026 SCCT/SCAI consensus states that CT-FFR has not been validated in stented segments and is not used for clinical decisions about them; nonstented arteries in the same patient can still be assessed (Weir-McCall 2026). Photon-counting and high-resolution scanners improve in-stent lumen depiction, and on-site CT-FFR in stented segments is under study.
Bypass grafts. Grafts introduce flow from a second source, competitive flow with the native vessel, and surgical clips. CT-FFR has not been validated in bypass grafts or grafted territories and is not used for clinical decisions in them (Weir-McCall 2026).
Total occlusion and collaterals. CT-FFR cannot model flow through an occluded segment or through collaterals, which are below the resolution of CCTA. The distal value in a collateral-filled vessel has no physiologic meaning, and the donor vessel's value may be falsely low because of the collateral demand.
Microvascular dysfunction. The model assumes a normal vasodilator response. Coronary microvascular dysfunction, common in women and in patients with diabetes, hypertension, or heart failure with preserved ejection fraction, is not captured by CT-FFR, and a normal CT-FFR does not exclude angina from microvascular disease. Dynamic CT perfusion or PET flow reserve, or invasive coronary function testing, answers that question.
Myocardial mass and territory. Resting flow is estimated from myocardial mass. Left ventricular hypertrophy raises the estimate, and infarcted myocardium lowers the true demand, so values in hypertrophied ventricles and in infarct territories are less reliable.
Special anatomy. Myocardial bridging, anomalous coronary origins with slit-like ostia, aneurysms, and fistulas present geometry and dynamic compression that resting models do not capture. Aortic stenosis alters coronary physiology, and CT-FFR is not established for that population.
| Situation | Reason CT-FFR is unreliable | Alternative |
|---|---|---|
| Motion or step artifact at the lesion | Distorted lumen geometry | CT perfusion; stress imaging; invasive FFR |
| Calcified lesion with uncertain lumen boundary | Segmentation error propagates into the value | CT perfusion; stress imaging |
| Poor opacification | Inaccurate lumen model; distal vessels lost | Repeat imaging or functional test |
| Stented segment, small or overlapping stents | Lumen not depicted | Stress imaging; invasive angiography |
| Bypass grafts | Dual-source flow not modeled | Stress imaging |
| Total occlusion with collaterals | Collateral flow not modeled | Viability and ischemia imaging; occlusion planning |
| Suspected microvascular angina | Normal microvascular response assumed | PET flow reserve; dynamic CT perfusion; invasive coronary function testing |
| Acute coronary syndrome culprit | Unstable lesion; physiology not the decision variable | Invasive angiography per ACS guidelines |
Settings in which CT-FFR is unreliable or not the right test.
Diagnostic accuracy of CT-FFR against invasive FFR
Three prospective multicenter trials established accuracy against invasive FFR with an older generation of the off-site computational fluid dynamics method. In all three, CT-FFR raised specificity over CCTA alone while keeping sensitivity high. DeFACTO missed its prespecified accuracy goal, and the improvement between DeFACTO and NXT reflects both software refinement and the requirement for nitroglycerin and strict image quality in NXT. PACIFIC compared CT-FFR with single-photon emission CT (SPECT) and PET in the same patients.
| Study | Population | CT-FFR performance | CCTA alone |
|---|---|---|---|
| DISCOVER-FLOW (2011) | 103 patients, 159 vessels; suspected or known CAD | Per vessel: accuracy 84.3%, sensitivity 87.9%, specificity 82.2%, PPV 73.9%, NPV 92.2%; AUC 0.90 | Per vessel: accuracy 58.5%, specificity 39.6%; AUC 0.75 |
| DeFACTO (2012) | 252 patients, 17 centers; suspected or known CAD | Per patient: accuracy 73%, sensitivity 90%, specificity 54%, PPV 67%, NPV 84%; AUC 0.81; prespecified accuracy goal not met | AUC 0.68 |
| NXT (2014) | 254 patients scheduled for invasive angiography; nitroglycerin required | Per patient: sensitivity 86%, specificity 79%; AUC 0.90 | Sensitivity 94%, specificity 34%; AUC 0.81 |
| NXT 320-detector substudy (2016) | 51 patients, 82 vessels | Per vessel: accuracy 83%, sensitivity 92%, specificity 79%, NPV 96%; AUC 0.93 (TAG 0.72) | AUC 0.68 |
| PACIFIC (2019) | 208 patients; CCTA, SPECT, and [15O]H2O PET with FFR in all vessels | Per vessel: accuracy 87%, sensitivity 90%, specificity 86%; AUC 0.94 (SPECT 0.70, PET 0.87); per patient AUC 0.92 (PET 0.91), all in evaluable vessels (83%); intention to diagnose, per vessel AUC 0.79 (PET 0.90) | Per vessel AUC 0.83 |
| Meta-analysis (2019) | 54 studies, 5,330 patients; CT-FFR, CT perfusion, TAG | Pooled per-vessel specificity 0.78; on-site and off-site similar | Pooled per-vessel specificity 0.61 |
Diagnostic accuracy of CT-FFR, with invasive FFR of 0.80 or less as the reference in all studies (Koo 2011; Min 2012; Nørgaard 2014; Ko 2016; Driessen 2019; Celeng 2019). AUC, area under the receiver operating characteristic curve; CAD, coronary artery disease; NPV, negative predictive value; PPV, positive predictive value; TAG, transluminal attenuation gradient.
Accuracy figures describe the vessels analyzed. Per-patient performance is lower than per-vessel performance because one false-positive vessel makes the whole patient false-positive. Intention-to-diagnose analysis is lower again because rejected studies count as failures.
Clinical utility and outcome studies of CT-FFR
The management value of CT-FFR has been tested in prospective cohorts, registries, and randomized trials. Their consistent finding is fewer invasive angiograms that show no obstructive disease, without an increase in death or myocardial infarction. Effects on total cost depend on the health system and on how selectively CT-FFR is ordered.
| Study | Design | Main findings |
|---|---|---|
| PLATFORM (2015) | 584 patients with new chest pain, 11 sites; consecutive cohorts of usual testing vs. CCTA with selective CT-FFR | Planned invasive stratum: no obstructive disease at angiography 12% vs. 73%; invasive angiography canceled in 61%; radiation 9.9 vs. 9.4 mSv; low and similar 90-day event rates |
| PROMISE CT-FFR substudy (2017) | CT-FFR computed blinded in 181 CCTA-arm patients referred to angiography | Discordance with CCTA stenosis 31%; 91% of revascularized patients had CT-FFR 0.80 or less; CT-FFR predicted revascularization or events better than severe stenosis |
| ADVANCE registry, 90 days (2018) | 5,083 patients with atherosclerosis on CCTA, 38 international sites | Management plan changed by CT-FFR in 66.9%; nonobstructive disease at angiography 14.4% with CT-FFR 0.80 or less vs. 43.8% above 0.80; 72.3% of patients with CT-FFR 0.80 or less who had angiography were revascularized; no death or MI within 90 days among 1,529 patients above 0.80 |
| ADVANCE registry, 1 year (2020) | Same cohort | Revascularization 38.4% with CT-FFR 0.80 or less vs. 5.6% above; cardiovascular death or MI 0.8% vs. 0.2% (relative risk 4.22) |
| FORECAST (2021) | 1,400 patients with stable chest pain, 11 UK centers; CCTA with selective CT-FFR vs. standard care pathways | Total cardiac costs at 9 months not different (+8%, P = 0.10); MACCE 10.2% vs. 10.6%; invasive angiography 19% vs. 25% (P = 0.01); CT-FFR used in 38% of the CCTA strategy arm |
| PRECISE (2023) | 2,103 stable symptomatic patients; risk-based strategy (deferred testing at minimal risk, CCTA with selective CT-FFR otherwise) vs. usual testing | Death, nonfatal MI, or catheterization without obstructive disease at about 1 year 4.2% vs. 11.3% (HR 0.35), driven by fewer catheterizations without obstructive disease |
| TARGET (2023) | 1,216 patients with 30% to 90% stenosis, 6 Chinese centers; on-site machine-learning CT-FFR pathway vs. standard care | Angiography without obstructive disease or without intervention 28.3% vs. 46.2%; angiography 69.2% vs. 79.4%; more revascularization (49.7% vs. 42.8%); 1-year MACE HR 0.88 (0.59–1.30) |
Clinical-utility and outcome studies of CT-FFR (Douglas 2015; Lu 2017; Fairbairn 2018; Patel MR 2020; Curzen 2021; Douglas 2023; Yang 2023). HR, hazard ratio; MACCE, major adverse cardiac and cerebrovascular events; MACE, major adverse cardiovascular events; MI, myocardial infarction.
Downstream invasive angiography. The common effect across these studies is a reduction in angiography that does not lead to treatment. PLATFORM showed the largest effect, in patients already planned for angiography. FORECAST, in a health system with a lower baseline rate of angiography, showed a smaller reduction (19% vs. 25%) and no cost saving. TARGET found fewer unnecessary angiograms but more revascularization overall, because physiologic testing directs procedures to lesions with abnormal values and does not necessarily reduce them.
Coverage and cost. In the United States, CT-FFR has a Category I Current Procedural Terminology code (75580), which replaced the earlier Category III codes, and Medicare administrative contractors cover it under local coverage determinations. At 1 year in PLATFORM, mean costs in the planned invasive stratum were 33% lower with CCTA and selective CT-FFR ($8,127 vs. $12,145), and did not differ in the planned noninvasive stratum when CT-FFR was assigned no cost (Douglas 2016). FORECAST found no significant difference in 9-month costs. The economic effect is greatest when CT-FFR replaces angiography that would otherwise find no obstructive disease, and smallest when it is ordered for lesions that would not have led to angiography.
Plaque, hemodynamic forces, and CT-FFR
Plaque characteristics and physiology are related. In a PACIFIC substudy of 257 vessels, positive remodeling and spotty calcification were associated with a lower invasive FFR independent of stenosis severity and plaque volume (Driessen 2020). Positive remodeling, spotty calcification, and a large plaque volume therefore make a moderate stenosis more likely to be hemodynamically significant. Low-attenuation plaque was not an independent predictor. The 40% lower limit for CT-FFR comes from the 2021 chest pain guideline (Gulati 2021). CAD-RADS 2.0 suggests functional assessment from 50% stenosis (CAD-RADS 3) and no further testing for 25% to 49% stenosis (Cury 2022).
Computational models produce more than pressure. Wall shear stress and axial plaque stress describe the forces that flow exerts on the plaque surface. In EMERALD, a case-control study of 72 patients with CCTA performed 1 month to 2 years before an acute coronary syndrome, culprit lesions had higher diameter stenosis, more adverse plaque characteristics, and lower CT-FFR than nonculprit lesions. Culprit lesions also had a larger ΔCT-FFR and higher wall shear stress and axial plaque stress. Adding these hemodynamic features to stenosis and plaque features improved discrimination of future culprits (Lee 2019). These parameters remain research measures and are not part of clinical reporting. CT-FFR does not identify a vulnerable plaque, and a normal value does not reduce the importance of high-risk plaque for preventive therapy.
Guideline and consensus positions on CT-FFR and CT perfusion
| Document | Position |
|---|---|
| 2021 AHA/ACC multisociety chest pain guideline | CT-FFR is reasonable for stenosis of 40% to 90% in a proximal or middle segment on CCTA, to diagnose vessel-specific ischemia and guide decisions about invasive angiography (Class 2a) |
| CAD-RADS 2.0 (2022) | Functional assessment by CT-FFR, CT perfusion, or stress testing for CAD-RADS 3 and 4A; no further testing for CAD-RADS 2 (25% to 49%); I+, I±, and I− modifiers when physiology is performed and interpretable |
| SCCT/SCAI expert consensus on CT-FFR (2026), endorsed by the ACC | CT-FFR for 50% to 90% stenosis when management may change; high-quality CCTA with heart-rate control and nitroglycerin; value read 2 cm distal to the stenosis and included in all reports; post-stenotic value above 0.80 low, 0.70 to 0.80 intermediate, and below 0.70 high probability of flow limitation; a drop of 0.12 or more with a value of 0.80 or less indicates high probability of lesion-specific flow limitation; reasonable in three-vessel obstructive disease; not validated in stents or bypass grafts |
| SCCT expert consensus on myocardial CT perfusion (2020) | Indications, stress protocols, static and dynamic techniques, interpretation, and reporting; no universal threshold for quantitative myocardial blood flow |
US guideline and society positions on CT-FFR and CT perfusion.
The guideline position places CT-FFR within a CCTA-first strategy for patients without known coronary disease: CCTA defines whether atherosclerosis and obstruction are present, and CT-FFR resolves intermediate lesions without a second test. In patients with known obstructive disease and persistent symptoms, stress imaging remains the usual test, and the choice of noninvasive test in established disease is covered on the chronic coronary disease page.
Principles of myocardial CT perfusion
Myocardial CT perfusion uses iodinated contrast as a perfusion tracer. CT attenuation rises linearly with iodine concentration, so the increase in myocardial attenuation during the first pass of a contrast bolus reflects the amount of iodine delivered to the myocardial blood pool and interstitium. During vasodilator stress, flow rises several-fold in myocardium supplied by normal arteries and much less in myocardium distal to a hemodynamically significant stenosis. The difference in iodine delivery appears as a region of lower attenuation, a perfusion defect.
Iodine is not an ideal flow tracer. It is not retained in myocytes, diffuses freely into the interstitium, and has an extraction fraction that falls as flow rises. Static CT perfusion samples a single moment near peak enhancement, when the difference between normal and ischemic myocardium is greatest; the result is relative, like SPECT. Dynamic CT perfusion samples the myocardium repeatedly through the first pass and fits a kinetic model to estimate myocardial blood flow in absolute units, like PET.
Two features distinguish CT perfusion from nuclear perfusion. Its spatial resolution is high enough to separate subendocardial from transmural defects, which nuclear imaging cannot do. It is combined with CCTA in the same session, so anatomy and physiology are read together. Its weaknesses are artifacts (beam hardening, motion, misregistration), the lower contrast-to-noise ratio of iodine in myocardium, the need for a vasodilator in the scanner, and added radiation.
| Feature | Static CT perfusion | Dynamic CT perfusion |
|---|---|---|
| Acquisition | One acquisition near peak myocardial enhancement | Repeated acquisitions through the first pass (shuttle mode or wide-detector coverage) |
| Output | Relative attenuation; visual or semiquantitative (transmural perfusion ratio) | Time-attenuation curves; myocardial blood flow (mL/min/g or mL/100 mL/min) and blood volume |
| Main dependence | Bolus timing | Registration across frames, motion, platform and kinetic model |
| Balanced multivessel ischemia | May be missed by relative comparison | Detected by globally low flow |
| Radiation | Lower; can be combined with CCTA in one acquisition | Higher; additional dynamic acquisition |
| Thresholds | Visual; relative | Platform-specific; no universal absolute flow threshold |
| Pooled accuracy (vessel level) | Sensitivity 0.72, specificity 0.90 | Sensitivity 0.85, specificity 0.81 |
Static and dynamic CT perfusion. Pooled accuracy against invasive FFR from the 2019 meta-analysis (Celeng 2019); threshold statement from the 2020 SCCT consensus (Patel AR 2020).
Stress agents, monitoring, and protocol design for CT perfusion
Stress agents. CT perfusion uses the vasodilators of nuclear stress testing: adenosine as a continuous infusion at 140 µg/kg/min, regadenoson as a single 0.4-mg intravenous bolus, or dipyridamole. Exercise is impractical in the scanner, and dobutamine raises heart rate and increases motion artifact. None of these drugs is labeled by the US Food and Drug Administration specifically for CT perfusion; they are used according to validated stress protocols adapted from nuclear cardiology. Caffeine and other methylxanthines blunt the response and are withheld for at least 12 hours. The contraindications are those of vasodilator stress: high-grade atrioventricular block or sick sinus syndrome without a pacemaker, active bronchospasm for adenosine and dipyridamole, systolic blood pressure below 90 mm Hg, and acute coronary syndrome. The drugs, their side effects, and their reversal are covered on the pharmacologic stress testing page.
Monitoring. During stress CT perfusion, heart rate and rhythm are monitored continuously, blood pressure is measured during and after stress, and symptoms are assessed. Hypotension, bronchospasm, or high-grade block takes priority over completing the acquisition.
Hemodynamic adequacy. A heart-rate rise and symptoms such as flushing or dyspnea indicate a vasodilator response; a blunted response raises the possibility of caffeine intake or an inadequate dose and lowers confidence in a normal study. The heart-rate rise can degrade CCTA image quality. Beta-blockers given for the CCTA are therefore timed relative to the stress acquisition, because beta-blockade reduces the hyperemic response and may mask ischemia.
Venous access. A continuous adenosine infusion given while contrast is power-injected requires two intravenous lines, one for the adenosine and one for the contrast. Regadenoson, given as a bolus, allows a single line with sequential injections.
Nitroglycerin and timing. Nitroglycerin and a vasodilator stress agent together can cause marked hypotension, and nitroglycerin alters myocardial attenuation. The SCCT perfusion consensus recommends about 10 to 20 minutes between nitroglycerin and the stress agent. A similar interval between rest and stress contrast acquisitions allows residual myocardial contrast to clear (Patel AR 2020).
Contrast. Foundational protocols use about 50 to 70 mL of iodinated contrast at 5 to 6 mL/s per perfusion acquisition, followed by 40 to 50 mL of saline. Faster, wider scanners use less. The total contrast for CCTA plus stress perfusion is about twice that of CCTA alone, which matters in chronic kidney disease.
| Sequence | Advantages | Disadvantages | Suited to |
|---|---|---|---|
| Rest first (CCTA with nitroglycerin and beta-blocker, then stress) | High-quality CCTA; stress perfusion can be omitted when the arteries are normal or have minimal plaque | Residual rest contrast in the myocardium reduces the contrast between normal and ischemic regions; beta-blocker and nitroglycerin effects on stress | Low to intermediate likelihood of coronary disease |
| Stress first (stress perfusion, then rest CCTA) | Stress images free of prior contrast and drug effects; best sensitivity for ischemia | Stress always performed; stress acquisition at a higher heart rate gives a less reliable coronary dataset | Known coronary disease, stents, high likelihood of ischemia |
| Stress only with combined CCTA and perfusion | Single contrast dose and acquisition; lowest radiation | No rest images to separate ischemia from scar; coronary images acquired during hyperemia | Selected protocols with late iodine enhancement for scar |
Sequences for combined CCTA and CT perfusion.
| Element | Consensus practice |
|---|---|
| Stress agent | Adenosine 140 µg/kg/min infusion, regadenoson 0.4 mg bolus, or dipyridamole; off-label for CT perfusion |
| Preparation | No caffeine for at least 12 hours; contraindications to vasodilator stress screened |
| Venous access | Two lines for continuous adenosine with power injection; one line for regadenoson |
| Monitoring | Continuous heart rate and rhythm; blood pressure during and after stress; symptoms |
| Nitroglycerin and stress agent | About 10 to 20 minutes apart |
| Rest and stress acquisitions | About 10 to 20 minutes apart |
| Contrast per acquisition | About 50 to 70 mL at 5 to 6 mL/s, then 40 to 50 mL saline; adapted to scanner and patient |
| Optional delayed acquisition | Late iodine enhancement for scar, several minutes after the last contrast injection |
Elements of a stress CT perfusion protocol (2020 SCCT consensus and nuclear stress practice).
Reading static CT perfusion
Static perfusion images are reconstructed in short-axis, two-chamber, and four-chamber planes, usually as thick averaged slabs to reduce noise, and displayed with a narrow window centered on myocardial attenuation. The reader compares regions on the same image, matches abnormalities to the 17-segment model and coronary territories, and compares stress with rest images.
A perfusion defect is described by location, extent (number of segments), severity, transmural extent, and reversibility. The SCCT consensus classifies a defect as transmural when it involves more than 50% of the wall thickness and nontransmural when it involves less. Ischemia typically begins in the subendocardium, where perfusion pressure is lowest and wall stress highest, so a mild stress defect is subendocardial and a severe one extends outward.
| Pattern | Stress | Rest | Interpretation |
|---|---|---|---|
| Reversible | Defect | Normal | Inducible ischemia |
| Fixed | Defect | Same defect | Infarct scar when supported by wall thinning, fat, calcification, or akinesis; confirmed by late iodine enhancement |
| Partially reversible | Defect | Smaller or milder defect | Scar with peri-infarct ischemia |
| Subendocardial | Less than 50% of wall thickness | — | Nontransmural; typical of moderate ischemia |
| Transmural | More than 50% of wall thickness | — | Severe ischemia or transmural scar |
| Artifact | Dark band adjacent to dense contrast, spine, or descending aorta; changes between phases or reconstructions | Variable | Beam hardening or motion; not reported as a defect |
Interpretation of CT perfusion abnormalities.
Semiquantitative indices reduce reader subjectivity. The transmural perfusion ratio divides subendocardial attenuation in a segment by the mean subepicardial attenuation of the whole myocardium; a low ratio indicates subendocardial hypoperfusion. Thresholds for such indices depend on scanner, protocol, and reconstruction and are applied only with local validation.
Fixed defects need corroboration before they are classified as scar. Wall thinning, subendocardial fat, calcification, aneurysm, akinesis on multiphase images, and late iodine enhancement all support infarction. A fixed basal inferolateral band without any of these features is more often beam hardening from the descending aorta and spine than an infarct.
Dynamic CT perfusion and myocardial blood flow
Dynamic CT perfusion acquires the heart repeatedly while the bolus passes from the left ventricle through the myocardium. Dual-source scanners alternate the table between two positions (shuttle mode) to cover the left ventricle; wide-detector scanners cover it in one rotation without table motion. The arterial input function is sampled in the left ventricular cavity or aorta, and myocardial time-attenuation curves are sampled in all segments. A kinetic model (deconvolution or a compartment model) yields myocardial blood flow and blood volume.
Units and reference values. CT myocardial blood flow is reported in mL/min/g (the convention of PET) or in mL/100 mL/min (per volume of tissue). With myocardial density near 1.05 g/mL, the two differ by about 5%, and 1.0 mL/min/g corresponds to about 105 mL/100 mL/min. In a 2024 meta-analysis of 23 studies against invasive FFR, stress myocardial blood flow averaged 1.39 mL/min/g (95% CI 1.25–1.54) in nonischemic regions and 0.92 mL/min/g (0.83–1.01) in ischemic regions. Per-patient pooled sensitivity was 0.82, specificity 0.86, and area under the curve 0.92, without significant differences between dual-source and single-source scanners or by body mass index. An abnormal dynamic perfusion study carried a pooled hazard ratio of 4.98 for adverse events (Kawaguchi 2024).
Thresholds. CT-derived flow values are lower than PET values in the same myocardium, because iodine extraction falls at high flow and because sampling and models differ. They also differ between vendors and software. The 2020 SCCT consensus states that no universal absolute threshold for ischemia is accepted (Patel AR 2020). Readers use platform-specific validated cutoffs and relative measures, such as the ratio of segmental flow to flow in a reference region of normal myocardium, together with the visual appearance and the coronary anatomy. A flow value validated on one platform is not applied to another.
Balanced ischemia and microvascular disease. Because flow is measured in all segments, dynamic perfusion can show globally reduced hyperemic flow in three-vessel or left main disease, which relative static imaging may display as uniform. Globally reduced flow with nonobstructive epicardial disease suggests microvascular dysfunction or diffuse atherosclerosis, analogous to a low global flow reserve on PET. Rest dynamic imaging, needed to compute flow reserve, adds radiation, so many CT protocols quantify stress flow only and use rest images for anatomy and scar.
Radiation. Dynamic acquisition adds dose to the CCTA. In a single-center series using a third-generation dual-source scanner, CCTA plus stress dynamic perfusion delivered a mean effective dose of 6.3 mSv (Fogante 2025). In CRESCENT-II, a tiered CT protocol (calcium score, CCTA if calcium was present, dynamic perfusion only for stenosis of 50% or more) gave a median cumulative dose of 3.1 mSv (Lubbers 2018). Dose depends heavily on scanner generation, body size, tube voltage, and the number of dynamic frames.
Artifacts in CT perfusion
Artifacts, particularly beam hardening and motion, can mimic perfusion defects and reduce diagnostic accuracy (Sliwicka 2023). These artifacts have typical locations and behaviors that distinguish them from a true defect.
| Artifact | Mechanism | Typical appearance | Distinguishing features and remedy |
|---|---|---|---|
| Beam hardening | Dense contrast in the left ventricle, descending aorta, or spine removes low-energy photons along certain projections | Dark band in the basal inferolateral or inferior wall or the septum, aligned with the dense structure | Changes with phase and reconstruction; does not follow a coronary territory; corrected by beam-hardening algorithms and high-energy monoenergetic or iodine-map images |
| Cardiac motion | Wall motion during the acquisition window | Hypoattenuating crescent, often lateral wall, with blurred edges | Differs between reconstructed phases; best-phase review |
| Misregistration (dynamic) | Respiratory or cardiac shift between frames | Implausible regional flow; jumping contours on cine review | Frame-by-frame review and motion correction; map rejected if registration fails |
| Mistimed static acquisition | Image acquired before or after peak enhancement | Uniformly low myocardial and aortic attenuation, or reduced contrast between regions | Low aortic attenuation reveals the timing failure; global ischemia is not diagnosed |
| Cone-beam and slab boundary | Geometric effects at detector edges or between stacked slabs | Band crossing the myocardium at a fixed axial level | Occurs at the same level in all segments; does not match a territory |
| Partial volume | Thin myocardium adjacent to blood pool or fat | Apparent defect at the apex or in thinned walls | Assessed with wall thickness and multiple planes |
Artifacts in myocardial CT perfusion.
A true defect persists across phases and reconstructions, conforms to a coronary territory, begins in the subendocardium, and matches a stenosis. An abnormality that meets none of these criteria is reported as artifact or as indeterminate, with the reason stated.
Dual-energy and spectral CT perfusion
Dual-energy, dual-layer, and photon-counting scanners separate photon energies and allow material decomposition. Iodine maps display iodine concentration, independent of the underlying tissue attenuation, and virtual monoenergetic images at high energy reduce beam hardening. In CT perfusion, iodine maps make defects more conspicuous and help separate true defects from beam-hardening bands, which shrink or vanish on monoenergetic and corrected images. Low-energy monoenergetic images increase iodine contrast and can improve detection of subtle subendocardial defects, although they add noise.
Spectral perfusion is usually performed as a static acquisition, sometimes during stress only, and a single-energy rest CCTA supplies the anatomy. Iodine concentration in myocardium can be measured in mg/mL, but thresholds differ between scanners and have not been standardized. Spectral imaging reduces artifacts without eliminating them; motion and timing errors affect iodine maps as they affect conventional images.
Transluminal attenuation gradient and other anatomy-derived indices
The transluminal attenuation gradient (TAG) is the slope of a linear regression of luminal attenuation against distance from the coronary ostium, expressed in Hounsfield units (HU) per 10 mm. During a single-beat acquisition on a wide-detector scanner, contrast concentration falls more steeply along a vessel with a hemodynamically significant stenosis, because less contrast reaches the distal segment in the same time. A steeper (more negative) gradient suggests flow limitation.
TAG requires no extra acquisition or software beyond centerline measurement, but its performance is modest. In the 320-detector substudy of NXT, TAG at the study's optimal threshold had per-vessel accuracy of 78%, sensitivity of 58%, and specificity of 86%, with an area under the curve of 0.72, compared with 0.93 for CT-FFR in the same vessels (Ko 2016). In the 2019 meta-analysis, TAG improved specificity over CCTA to 0.77 (Celeng 2019). TAG depends on scanner coverage and timing, is affected by calcium and noise, and has not been standardized. Related indices, such as corrected contrast opacification and the ratio of coronary lumen volume to myocardial mass, are research measures.
Diagnostic accuracy and prognosis of CT perfusion
| Study | Design | Main findings |
|---|---|---|
| CORE320 (2014) | 381 patients, 16 centers; 320-detector CCTA plus static adenosine CT perfusion before invasive angiography; reference stenosis of 50% or more with a SPECT defect | Combined CCTA and CT perfusion AUC 0.87 (0.93 without prior CAD); stenosis plus defect sensitivity 80%, specificity 74% |
| CORE320 CT perfusion vs. SPECT (2014) | Same cohort; reference invasive angiographic stenosis | CT perfusion more sensitive than SPECT (88% vs. 62%), less specific (55% vs. 67%) |
| CORE320 prognosis (2017) | 379 patients followed 2 years | MACE-free survival 94% with negative vs. 82% with positive CCTA and CT perfusion, similar to invasive angiography plus SPECT (93% vs. 77%); AUC 0.68 vs. 0.71 (P = 0.36) |
| Regadenoson CT perfusion vs. SPECT (2015) | 124 patients randomized to sequence, multivendor | Regadenoson CT perfusion noninferior to SPECT for ischemia in 2 or more segments; agreement 0.87; sensitivity 0.90, specificity 0.84 |
| CT vs. CMR perfusion, CORE320 substudy (2018) | 92 patients with both studies | Against angiography plus SPECT: CT sensitivity 92% vs. CMR 83%; specificity 45% vs. 70% (P < 0.01) |
| PERFECTION (2019) | 147 patients with invasive FFR; CCTA, CT-FFR, and static stress CT perfusion | Per-patient AUC: CCTA 0.90, CCTA plus CT-FFR 0.94, CCTA plus CT perfusion 0.93 (no difference between the two physiologic methods); both raised specificity over CCTA |
| Perfusion modality meta-analysis (2015) | 37 studies, 2,048 patients, invasive FFR reference | Vessel-level negative likelihood ratio: CT 0.22, CMR 0.16, PET 0.15, SPECT 0.47 |
| CRESCENT-II (2018) | 268 patients with stable angina randomized to tiered CT with dynamic perfusion vs. functional testing | Invasive angiography without a Class I revascularization indication 1.5% vs. 7.2%; further testing 13% vs. 37%; adverse events 3% vs. 3% |
| Dynamic CT perfusion meta-analysis (2024) | 23 studies, invasive FFR reference | Per-patient sensitivity 0.82, specificity 0.86, AUC 0.92; prognostic hazard ratio 4.98 |
Accuracy, comparative, and outcome studies of CT perfusion (Rochitte 2014; George 2014; Chen 2017; Cury 2015; Rief 2018; Pontone 2019; Takx 2015; Lubbers 2018; Kawaguchi 2024). AUC, area under the curve; CAD, coronary artery disease; MACE, major adverse cardiovascular events.
Adding CT perfusion to CCTA raises specificity over CCTA alone. Static CT perfusion was less specific than SPECT in CORE320 and less specific than stress cardiovascular magnetic resonance (CMR) perfusion in a CORE320 substudy, although overall accuracy did not differ significantly. A combined CT result also predicts events as well as invasive angiography with SPECT. The trials are smaller than those of CT-FFR, and no randomized trial has compared CT perfusion with CT-FFR as management strategies.
Choosing among CT-FFR, CT perfusion, and other ischemia tests
CT-FFR and CT perfusion both add physiology to CCTA, from different sources of information. CT-FFR is computed from the anatomy of a resting study and needs no drug, extra contrast, or extra radiation; it fails when the lumen cannot be modeled. CT perfusion images the myocardium and requires a stress agent and an additional acquisition; it remains informative when calcium or stents make the lumen uncertain, and it shows the extent and transmurality of ischemia and, with delayed imaging, scar. The two outputs are not interchangeable: CT-FFR estimates a lesion's pressure loss, and CT perfusion shows the myocardial consequence.
| Test | What it measures | Strengths | Limitations |
|---|---|---|---|
| CT-FFR | Modeled lesion-specific pressure ratio | No added acquisition, drug, or dose; vessel-specific; ranks lesions; large outcome evidence | Depends on image quality; unreliable in stents, grafts, occlusions, uncertain calcified lumen; assumes normal microcirculation |
| Static stress CT perfusion | Relative myocardial iodine distribution | Shows defect location and transmurality; interpretable with heavy calcium and stents | Beam-hardening and motion artifacts; balanced ischemia; drug and added dose |
| Dynamic stress CT perfusion | Myocardial blood flow (mL/min/g) | Quantitative; detects balanced and microvascular disease | Higher dose; registration; platform-specific thresholds; limited availability |
| SPECT | Relative tracer uptake | Widely available; long prognostic record | Attenuation artifacts; lower sensitivity and specificity than PET; balanced ischemia |
| PET | Absolute myocardial blood flow and flow reserve | Highest accuracy among perfusion methods; detects multivessel and microvascular disease | Availability and cost; no anatomy without added CCTA |
| Stress CMR | First-pass gadolinium perfusion with LGE | No radiation; scar and viability in the same study | Contraindications; longer study; availability |
| Invasive FFR | Measured pressure ratio during hyperemia | Reference standard; guides PCI in the same procedure | Invasive; requires angiography |
Comparison of physiologic tests for coronary disease. CMR, cardiovascular magnetic resonance; LGE, late gadolinium enhancement.
The choice depends on the CCTA findings and the clinical question. When a diagnostic CCTA shows an intermediate stenosis in a proximal or middle segment and the lumen is clearly defined, CT-FFR requires nothing further from the patient. When dense calcium or stents prevent confident segmentation, or when the extent of ischemia or the presence of scar matters, stress CT perfusion, PET, or stress CMR is preferred. When microvascular disease or balanced ischemia is the concern, quantitative flow by PET or dynamic CT perfusion is needed. In PACIFIC, CT-FFR outperformed SPECT and matched PET on a per-patient basis when vessels could be analyzed; PET led in the intention-to-diagnose analysis, which counted unanalyzable vessels as errors (Driessen 2019). Nuclear perfusion methods are covered on the myocardial perfusion imaging page.
Late iodine enhancement: myocardial scar on CT
Iodinated contrast, like gadolinium, is an extracellular agent. It distributes into the interstitium and washes out slowly where the extracellular space is expanded, in infarct scar, fibrosis, or infiltration. Several minutes after injection, scarred myocardium therefore has higher attenuation than normal myocardium, an appearance called late iodine enhancement (LIE) or delayed enhancement. The pattern follows the same rules as late gadolinium enhancement (LGE) on CMR: subendocardial or transmural enhancement in a coronary territory indicates infarction, and midwall, subepicardial, or diffuse enhancement indicates nonischemic disease.
The main limitation is low tissue contrast. The difference in attenuation between scar and normal myocardium is small, often a few tens of Hounsfield units, and image noise is high. Protocols therefore use low tube voltage to bring the photon spectrum closer to the K-edge of iodine and increase its attenuation, with higher tube current. Thick slices and iterative or deep-learning reconstruction control noise (Steffani 2026). The delay after the last contrast injection is usually several minutes; published protocols range from about 3 to 15 minutes, chosen for the target disease. Spectral and photon-counting scanners add iodine maps and low-energy monoenergetic images that increase conspicuity.
Accuracy. In a 2025 meta-analysis of 14 studies (526 patients, 5,758 segments) using CMR LGE as the reference, LIE had a pooled patient-level sensitivity of 0.96 and specificity of 0.95 (area under the curve 0.98). Segment-level sensitivity was 0.86 and specificity 0.98 (Gatti 2025). Detection of small or subendocardial scar is more operator- and protocol-dependent than with CMR.
Uses. LIE adds scar assessment to a CT examination when CMR is contraindicated or unavailable: patients with nonconditional devices, claustrophobia, or severe arrhythmia. Applications include distinguishing ischemic from nonischemic cardiomyopathy, defining infarct extent before revascularization, and scar mapping before ventricular tachycardia ablation. LIE also contributes to the evaluation of troponin elevation with normal coronary arteries (myocarditis, infarction with nonobstructive arteries) and to the detection of left ventricular thrombus, which does not enhance. In acute infarction, the arterial phase may show early hypoenhancement of the infarct core (microvascular obstruction), and the delayed phase shows LIE, sometimes with a persistent dark core.
Integration with perfusion. A rest–stress CT protocol with a delayed acquisition separates ischemia from scar in one examination: a reversible stress defect without LIE indicates ischemia in viable myocardium, while a fixed defect with transmural LIE indicates nonviable scar. Viability assessment by CMR, PET, and nuclear imaging is covered on the myocardial viability page.
Myocardial extracellular volume by CT
Extracellular volume (ECV) is the fraction of myocardial tissue made up of extracellular space, the interstitium plus capillary plasma. It rises with diffuse fibrosis and with infiltration, most strikingly amyloid deposition, and it is measured by comparing the change in myocardial attenuation after contrast with the change in blood attenuation, corrected for hematocrit. At contrast equilibrium, the ratio of iodine concentration in myocardium to that in blood plasma equals the ratio of their extracellular fractions.
| Element | Method |
|---|---|
| Formula | ECV = (1 − hematocrit) × (ΔHU myocardium ÷ ΔHU blood), where ΔHU is postcontrast minus precontrast attenuation |
| Precontrast acquisition | Noncontrast gated scan (often the calcium-score acquisition) or virtual noncontrast images from spectral CT |
| Postcontrast acquisition | Delayed gated scan at near-equilibrium, typically 3 to 15 minutes after contrast |
| Regions of interest | Septal or segmental myocardium avoiding blood-pool partial volume; left ventricular blood pool |
| Hematocrit | Measured on the day of the scan; synthetic hematocrit from blood-pool attenuation is an alternative under study |
| Spectral alternative | ECV from iodine concentration on a single delayed acquisition, avoiding subtraction and misregistration |
Measurement of myocardial extracellular volume by CT.
Validation and values. In patients with systemic amyloidosis and aortic stenosis, CT ECV correlated with CMR ECV (r² 0.85 at 5 minutes and 0.74 at 15 minutes), and ECV was 54% ± 11% in amyloidosis and 28% ± 4% in aortic stenosis, without overlap (Treibel 2015). In 109 patients with severe aortic stenosis evaluated for transcatheter aortic valve replacement (TAVR), 15% had transthyretin amyloid on bone scintigraphy. CT ECV was 28% ± 2% in controls, 32% ± 3% with Perugini grade 0, 34% ± 4% with grade 1, and 43% ± 6% with grade 2, and detected amyloid with an area under the curve of 0.87 (Scully 2020). In a regional analysis, median global CT ECV was 26.1% in controls, 29.1% in aortic stenosis, and 37.4% in aortic stenosis with transthyretin amyloid; ECV was higher at the base, the inferoseptum, and the subendocardium (Patel KP 2024).
Prognosis in aortic stenosis. In a meta-analysis of 10 studies (1,223 patients undergoing valve replacement), the pooled CT ECV cutoff for elevated values was 30.7%. Patients above it had more cardiovascular events at about 18 months (43.4% vs. 14.0%; odds ratio 4.3) (Faggiano 2025). Because TAVR planning already requires a gated contrast CT, adding a noncontrast and a delayed acquisition allows ECV measurement with modest added dose. An elevated value raises the question of transthyretin amyloid, which is then pursued with scintigraphy and light-chain testing as described on the cardiac amyloidosis page.
ECV = (1 − hematocrit) × (myocardial ΔHU ÷ blood ΔHU). With hematocrit 40%, a myocardial rise of 50 HU and a blood rise of 100 HU give ECV = 0.60 × 0.50 = 30%. Interpretive ranges come from aortic stenosis and amyloidosis cohorts (Treibel 2015; Scully 2020; Faggiano 2025); reference values depend on scanner, kilovoltage, and delay.
Limitations. Subtraction of two acquisitions doubles noise and is sensitive to misregistration, so regions are drawn on matched slices and in thick myocardium. Low tube voltage and contrast timing change the absolute values. Hematocrit must be current. ECV does not distinguish fibrosis from amyloid or edema; it measures expansion of the extracellular space, and its meaning depends on the clinical setting.
Reporting CT-FFR and CT perfusion
Physiologic results enter the CAD-RADS 2.0 report as the ischemia modifier, added after the stenosis category and plaque burden. The modifier is I+ for a CT-FFR of 0.75 or less or a reversible perfusion defect, I± for a CT-FFR of 0.76 to 0.80 or an indeterminate perfusion study, and I− for a CT-FFR above 0.80 or a study without ischemia. A fixed defect without a reversible component counts as a study without ischemia. The modifier does not change the stenosis category, and it is used only when CT-FFR or CT perfusion was actually performed and is interpretable; a visual impression that a stenosis is nonischemic does not qualify for I−. The full CAD-RADS 2.0 system, with a tool that assembles the category, plaque burden, and modifiers, is on the coronary CT angiography page.
A CT-FFR report states, for a tested lesion, the vessel and segment, the anatomic stenosis, the value 2 cm distal to the stenosis, the band, the translesional drop when the value is borderline, the pattern along the vessel (focal, diffuse, or serial), the platform, and any limitation at the lesion. "60% proximal left anterior descending stenosis; CT-FFR 0.74 at 2 cm distal (I+), focal step of 0.18 across the lesion" supports a management decision; "CT-FFR 0.74" alone does not.
A CT perfusion report states the indication, stress agent and dose, hemodynamic response, sequence (rest-first or stress-first), technique (static, dynamic, or spectral), contrast, and image quality. Findings give defect location by segment and territory, extent, severity, transmural extent, and reversibility, with the concordant coronary lesion, any artifacts recognized and excluded, and for dynamic studies the flow values with the platform's reference. Late iodine enhancement, when acquired, is reported by pattern and transmural extent.
Sources of error in CT-FFR and CT perfusion
- Reporting the lowest value at the distal tip of the vessel as the lesion value. The lesion value is read 2 cm distal to the stenosis; the tip reflects tapering and diffuse disease.
- Classifying a CT-FFR of 0.76 to 0.80 as positive or negative. It is borderline (I±) and is interpreted with the translesional drop, location, vessel size, plaque, and symptoms.
- Accepting a value from a segment with motion, step artifact, or an uncertain calcified lumen. The model cannot correct geometry that the images did not capture.
- Omitting nitroglycerin from a CCTA intended for CT-FFR. The smaller lumen lowers the computed value.
- Assigning the whole distal pressure loss in a vessel with tandem lesions to the first lesion.
- Requesting CT-FFR for minimal plaque, a total occlusion, left main stenosis, or a suspected acute culprit, where it does not inform the decision.
- Using CT-FFR to decide on stented segments or bypass grafts, in which it has not been validated.
- Treating a normal CT-FFR as excluding angina. Microvascular dysfunction is not modeled.
- Equating an abnormal CT-FFR in a small distal branch with an indication for angiography.
- Reporting a basal inferolateral band adjacent to the descending aorta as ischemia. Beam hardening changes between phases and does not follow a territory.
- Diagnosing multivessel ischemia on a static acquisition with low aortic attenuation. The acquisition was mistimed.
- Applying a myocardial blood flow threshold from one vendor's platform to another.
- Reading a normal rest perfusion study as excluding inducible ischemia. Ischemia requires stress imaging.
- Classifying a fixed defect as an infarct without wall thinning, fat, akinesis, or late iodine enhancement.
- Giving nitroglycerin and a vasodilator stress agent together, or acquiring stress immediately after rest contrast.
- Assigning an ischemia modifier when no physiology test was performed.
- Calculating ECV with an old hematocrit or with regions drawn on misregistered slices.
References
- Weir-McCall JR, Koweek L, Suchá D, et al. Fractional flow reserve in coronary computed tomography angiography: an expert consensus document of the Society of Cardiovascular Computed Tomography (SCCT) and the Society for Cardiovascular Angiography and Interventions (SCAI). Endorsed by the American College of Cardiology (ACC). J Cardiovasc Comput Tomogr. 2026;20:316–332. doi:10.1016/j.jcct.2026.05.006
- Cury RC, Leipsic J, Abbara S, et al. CAD-RADS 2.0 – 2022 Coronary Artery Disease–Reporting and Data System: an expert consensus document of the Society of Cardiovascular Computed Tomography (SCCT), the American College of Cardiology (ACC), the American College of Radiology (ACR), and the North America Society of Cardiovascular Imaging (NASCI). J Cardiovasc Comput Tomogr. 2022;16:536–557. doi:10.1016/j.jcct.2022.07.002
- Gulati M, Levy PD, Mukherjee D, et al. 2021 AHA/ACC/ASE/CHEST/SAEM/SCCT/SCMR guideline for the evaluation and diagnosis of chest pain: a report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation. 2021;144:e368–e454. doi:10.1161/CIR.0000000000001029
- Patel AR, Bamberg F, Branch K, et al. Society of Cardiovascular Computed Tomography expert consensus document on myocardial computed tomography perfusion imaging. J Cardiovasc Comput Tomogr. 2020;14:87–100. doi:10.1016/j.jcct.2019.10.003
- Taylor CA, Fonte TA, Min JK. Computational fluid dynamics applied to cardiac computed tomography for noninvasive quantification of fractional flow reserve: scientific basis. J Am Coll Cardiol. 2013;61:2233–2241. doi:10.1016/j.jacc.2012.11.083
- Tonino PA, De Bruyne B, Pijls NH, et al. Fractional flow reserve versus angiography for guiding percutaneous coronary intervention. N Engl J Med. 2009;360:213–224. doi:10.1056/NEJMoa0807611
- Koo BK, Erglis A, Doh JH, et al. Diagnosis of ischemia-causing coronary stenoses by noninvasive fractional flow reserve computed from coronary computed tomographic angiograms: results from the prospective multicenter DISCOVER-FLOW (Diagnosis of Ischemia-Causing Stenoses Obtained Via Noninvasive Fractional Flow Reserve) study. J Am Coll Cardiol. 2011;58:1989–1997. doi:10.1016/j.jacc.2011.06.066
- Min JK, Leipsic J, Pencina MJ, et al. Diagnostic accuracy of fractional flow reserve from anatomic CT angiography. JAMA. 2012;308:1237–1245. doi:10.1001/2012.jama.11274
- Nørgaard BL, Leipsic J, Gaur S, et al. Diagnostic performance of noninvasive fractional flow reserve derived from coronary computed tomography angiography in suspected coronary artery disease: the NXT trial (Analysis of Coronary Blood Flow Using CT Angiography: Next Steps). J Am Coll Cardiol. 2014;63:1145–1155. doi:10.1016/j.jacc.2013.11.043
- Nørgaard BL, Gaur S, Leipsic J, et al. Influence of coronary calcification on the diagnostic performance of CT angiography derived FFR in coronary artery disease: a substudy of the NXT trial. JACC Cardiovasc Imaging. 2015;8:1045–1055. doi:10.1016/j.jcmg.2015.06.003
- Driessen RS, Danad I, Stuijfzand WJ, et al. Comparison of coronary computed tomography angiography, fractional flow reserve, and perfusion imaging for ischemia diagnosis. J Am Coll Cardiol. 2019;73:161–173. doi:10.1016/j.jacc.2018.10.056
- Danad I, Raijmakers PG, Driessen RS, et al. Comparison of coronary CT angiography, SPECT, PET, and hybrid imaging for diagnosis of ischemic heart disease determined by fractional flow reserve. JAMA Cardiol. 2017;2:1100–1107. doi:10.1001/jamacardio.2017.2471
- Driessen RS, de Waard GA, Stuijfzand WJ, et al. Adverse plaque characteristics relate more strongly with hyperemic fractional flow reserve and instantaneous wave-free ratio than with resting instantaneous wave-free ratio. JACC Cardiovasc Imaging. 2020;13:746–756. doi:10.1016/j.jcmg.2019.06.013
- Douglas PS, Pontone G, Hlatky MA, et al. Clinical outcomes of fractional flow reserve by computed tomographic angiography-guided diagnostic strategies vs. usual care in patients with suspected coronary artery disease: the prospective longitudinal trial of FFRCT: outcome and resource impacts study (PLATFORM). Eur Heart J. 2015;36:3359–3367. doi:10.1093/eurheartj/ehv444
- Douglas PS, De Bruyne B, Pontone G, et al. 1-year outcomes of FFRCT-guided care in patients with suspected coronary disease: the PLATFORM study. J Am Coll Cardiol. 2016;68:435–445. doi:10.1016/j.jacc.2016.05.057
- Schott J, Allen O, Rollins Z, et al. Late outcomes of patients in the emergency department with acute chest pain evaluated with computed tomography-derived fractional flow reserve. Am J Cardiol. 2024;226:65–71. doi:10.1016/j.amjcard.2024.06.008
- Lu MT, Ferencik M, Roberts RS, et al. Noninvasive FFR derived from coronary CT angiography: management and outcomes in the PROMISE trial. JACC Cardiovasc Imaging. 2017;10:1350–1358. doi:10.1016/j.jcmg.2016.11.024
- Fairbairn TA, Nieman K, Akasaka T, et al. Real-world clinical utility and impact on clinical decision-making of coronary computed tomography angiography-derived fractional flow reserve: lessons from the ADVANCE Registry. Eur Heart J. 2018;39:3701–3711. doi:10.1093/eurheartj/ehy530
- Patel MR, Nørgaard BL, Fairbairn TA, et al. 1-year impact on medical practice and clinical outcomes of FFRCT: the ADVANCE Registry. JACC Cardiovasc Imaging. 2020;13:97–105. doi:10.1016/j.jcmg.2019.03.003
- Curzen N, Nicholas Z, Stuart B, et al. Fractional flow reserve derived from computed tomography coronary angiography in the assessment and management of stable chest pain: the FORECAST randomized trial. Eur Heart J. 2021;42:3844–3852. doi:10.1093/eurheartj/ehab444
- Douglas PS, Nanna MG, Kelsey MD, et al. Comparison of an initial risk-based testing strategy vs usual testing in stable symptomatic patients with suspected coronary artery disease: the PRECISE randomized clinical trial. JAMA Cardiol. 2023;8:904–914. doi:10.1001/jamacardio.2023.2595
- Yang J, Shan D, Wang X, et al. On-site computed tomography-derived fractional flow reserve to guide management of patients with stable coronary artery disease: the TARGET randomized trial. Circulation. 2023;147:1369–1381. doi:10.1161/CIRCULATIONAHA.123.063996
- Kueh SH, Mooney J, Ohana M, et al. Fractional flow reserve derived from coronary computed tomography angiography reclassification rate using value distal to lesion compared to lowest value. J Cardiovasc Comput Tomogr. 2017;11:462–467. doi:10.1016/j.jcct.2017.09.009
- Thangavel S, Madsen KT, Rønnow Sand NP, et al. Selective FFRCT testing in suspected stable angina in clinical practice: initial experiences. Int J Cardiovasc Imaging. 2024;40:2213–2220. doi:10.1007/s10554-024-03214-8
- Lee JM, Choi G, Koo BK, et al. Identification of high-risk plaques destined to cause acute coronary syndrome using coronary computed tomographic angiography and computational fluid dynamics. JACC Cardiovasc Imaging. 2019;12:1032–1043. doi:10.1016/j.jcmg.2018.01.023
- Celeng C, Leiner T, Maurovich-Horvat P, et al. Anatomical and functional computed tomography for diagnosing hemodynamically significant coronary artery disease: a meta-analysis. JACC Cardiovasc Imaging. 2019;12:1316–1325. doi:10.1016/j.jcmg.2018.07.022
- Ko BS, Wong DT, Nørgaard BL, et al. Diagnostic performance of transluminal attenuation gradient and noninvasive fractional flow reserve derived from 320-detector row CT angiography to diagnose hemodynamically significant coronary stenosis: an NXT substudy. Radiology. 2016;279:75–83. doi:10.1148/radiol.2015150383
- Rochitte CE, George RT, Chen MY, et al. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography: the CORE320 study. Eur Heart J. 2014;35:1120–1130. doi:10.1093/eurheartj/eht488
- George RT, Mehra VC, Chen MY, et al. Myocardial CT perfusion imaging and SPECT for the diagnosis of coronary artery disease: a head-to-head comparison from the CORE320 multicenter diagnostic performance study. Radiology. 2014;272:407–416. doi:10.1148/radiol.14140806
- Chen MY, Rochitte CE, Arbab-Zadeh A, et al. Prognostic value of combined CT angiography and myocardial perfusion imaging versus invasive coronary angiography and nuclear stress perfusion imaging in the prediction of major adverse cardiovascular events: the CORE320 multicenter study. Radiology. 2017;284:55–65. doi:10.1148/radiol.2017161565
- Pontone G, Baggiano A, Andreini D, et al. Stress computed tomography perfusion versus fractional flow reserve CT derived in suspected coronary artery disease: the PERFECTION study. JACC Cardiovasc Imaging. 2019;12:1487–1497. doi:10.1016/j.jcmg.2018.08.023
- Cury RC, Kitt TM, Feaheny K, et al. A randomized, multicenter, multivendor study of myocardial perfusion imaging with regadenoson CT perfusion vs single photon emission CT. J Cardiovasc Comput Tomogr. 2015;9:103–112. doi:10.1016/j.jcct.2015.01.002
- Rief M, Chen MY, Vavere AL, et al. Coronary artery disease: analysis of diagnostic performance of CT perfusion and MR perfusion imaging in comparison with quantitative coronary angiography and SPECT—multicenter prospective trial. Radiology. 2018;286:461–470. doi:10.1148/radiol.2017162447
- Takx RA, Blomberg BA, El Aidi H, et al. Diagnostic accuracy of stress myocardial perfusion imaging compared to invasive coronary angiography with fractional flow reserve meta-analysis. Circ Cardiovasc Imaging. 2015;8:e002666. doi:10.1161/CIRCIMAGING.114.002666
- Kawaguchi Y, Kato S, Horita N, et al. Value of dynamic computed tomography myocardial perfusion in CAD: a systematic review and meta-analysis. Eur Heart J Cardiovasc Imaging. 2024;25:1675–1685. doi:10.1093/ehjci/jeae118
- Sliwicka O, Sechopoulos I, Baggiano A, Pontone G, Nijveldt R, Habets J. Dynamic myocardial CT perfusion imaging—state of the art. Eur Radiol. 2023;33:5509–5525. doi:10.1007/s00330-023-09550-y
- Lubbers M, Coenen A, Kofflard M, et al. Comprehensive cardiac CT with myocardial perfusion imaging versus functional testing in suspected coronary artery disease: the multicenter, randomized CRESCENT-II trial. JACC Cardiovasc Imaging. 2018;11:1625–1636. doi:10.1016/j.jcmg.2017.10.010
- Fogante M, Paolini E, Cela F, et al. Feasibility, added value, and radiation dose of combined coronary CT angiography and stress dynamic CT myocardial perfusion imaging in moderate coronary artery disease: a real-world study. J Cardiovasc Dev Dis. 2025;12:241. doi:10.3390/jcdd12070241
- Gatti M, De Filippo O, Cura Curà G, et al. Diagnostic accuracy of late iodine enhancement on cardiac CT for myocardial tissue characterization: a systematic review and meta-analysis. Eur Radiol. 2025;35:3054–3067. doi:10.1007/s00330-024-11283-5
- Steffani S, Piscione M, Gaudio D, et al. Diagnostic value and operational recommendations for late iodine enhancement and ECV quantification in single-energy computed tomography: a narrative review. Diagnostics (Basel). 2026;16:2547. doi:10.3390/diagnostics16162547
- Treibel TA, Bandula S, Fontana M, et al. Extracellular volume quantification by dynamic equilibrium cardiac computed tomography in cardiac amyloidosis. J Cardiovasc Comput Tomogr. 2015;9:585–592. doi:10.1016/j.jcct.2015.07.001
- Scully PR, Patel KP, Saberwal B, et al. Identifying cardiac amyloid in aortic stenosis: ECV quantification by CT in TAVR patients. JACC Cardiovasc Imaging. 2020;13:2177–2189. doi:10.1016/j.jcmg.2020.05.029
- Patel KP, Scully PR, Saberwal B, et al. Regional distribution of extracellular volume quantified by cardiac CT in aortic stenosis: insights into disease mechanisms and impact on outcomes. Circ Cardiovasc Imaging. 2024;17:e015996. doi:10.1161/CIRCIMAGING.123.015996
- Faggiano A, Gherbesi E, Carugo S, et al. Prognostic value of myocardial computed tomography-derived extracellular volume in severe aortic stenosis requiring aortic valve replacement: a systematic review and meta-analysis. Eur Heart J Cardiovasc Imaging. 2025;26:518–531. doi:10.1093/ehjci/jeae324
- Pontone G, Weir-McCall JR, Baggiano A, et al. Determinants of rejection rate for coronary CT angiography fractional flow reserve analysis. Radiology. 2019;292:597–605. doi:10.1148/radiol.2019182673